Evidence map›Paper›PMID 28217224›Full record

ArticleJournal of arrhythmia2017

Mortality and predictors of appropriate implantable cardioverter defibrillator therapy in Japanese patients with Multicenter Automatic Defibrillator Implantation Trial II criteria.

Yoshimori An, Kenji Ando, Yoshimitsu Soga, Akihiro Nomura, Michio Nagashima, Kentaro Hayashi, Yu Makihara, Masato Fukunaga, Ken-Ichi Hiroshima, Masakiyo Nobuyoshi and 1 more

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Yoshimori AnDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Kenji AndoDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Yoshimitsu SogaDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Akihiro NomuraDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Michio NagashimaDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Kentaro HayashiDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Yu MakiharaDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Masato FukunagaDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Ken-Ichi HiroshimaDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Masakiyo NobuyoshiDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Masahiko GoyaDepartment of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Kokura Memorial Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundData regarding long-term mortality and factors influencing appropriate therapies in Japanese patients with implantable cardioverter defibrillators (ICD), who satisfy the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) criteria for primary prevention, remain scarce.

methodsA total of 118 consecutive patients who underwent ICD implantation without any prior ventricular arrhythmic event, from January 2000 to December 2012, were enrolled based on the MADIT II criteria: left ventricular ejection fraction (LVEF) of ≤30% with ischemic heart disease and at least 4 weeks after a myocardial infarction. We investigated the mortality and factors influencing appropriate ICD therapies in this population.

resultsThe mean age was 69±10 years, and the mean LVEF was 25.1±4.5%. During the median follow up of 1406 days, the mortality rate was 20%, and the incidence of appropriate ICD therapy was 37% at 3 years. Multivariate analysis by using Cox regression model showed that left ventricular diastolic diameter ≥60 mm (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.07-5.38;

conclusionsThe mortality and incidence of appropriate ICD therapy were 20% and 37%, respectively, at 3 years in Japanese patients who met the MADIT II criteria during ICD implantation for primary prevention of sudden cardiac death. The presence of NSVT and dilated left ventricle independently predicted the incidence of appropriate ICD therapy after implantation.

Indexed as

Implantable cardioverter defibrillatorPrimary preventionVentricular tachyarrhythmia

Identifiers

PMID28217224
PMCPMC5300836
OpenAlexW2472457071

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.