ArticleAnnals of surgical oncology2017
Optical See-Through Cancer Vision Goggles Enable Direct Patient Visualization and Real-Time Fluorescence-Guided Oncologic Surgery.
Article in Annals of surgical oncology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 1 synthesis or guideline pooled it, 41 citations in OpenAlex.
- Pooled it
- Intraoperative measurement of breast-conserving surgery margins: surgical application.Breast cancer research : BCR · 2026Review
- Emerging uses of 5-aminolevulinic-acid-induced protoporphyrin IX in medicine: a review of multifaceted, ubiquitous, molecular diagnostic, therapeutic, and theranostic opportunities.Journal of biomedical optics · 2025Review
- An Augmented Reality Visor for Intraoperative Visualization, Guidance, and Temperature Monitoring Using Fluorescence.Journal of biophotonics · 2025Article
- Frugal engineering-inspired wearable augmented reality goggle system enables fluorescence-guided cancer surgery.Scientific reports · 2024Article
- Fluorescent Probes for Imaging in Humans: Where Are We Now?ACS nano · 2023Review
- Fluorescence-guided surgical system using holographic display: from phantom studies to canine patients.Journal of biomedical optics · 2023Article
- Image Translation of Breast Ultrasound to Pseudo Anatomical Display by CycleGAN.Bioengineering (Basel, Switzerland) · 2023Article
- Updates on fluorescent probes and open-field imaging methods for fluorescence-guided cytoreductive surgery for epithelial ovarian cancer: A review.BJOG : an international journal of obstetrics and gynaecology · 2022Review
- Algorithms and instrumentation for rapid spatial frequency domain fluorescence diffuse optical imaging.Journal of biomedical optics · 2022Article
- Design and Testing of Augmented Reality-Based Fluorescence Imaging Goggle for Intraoperative Imaging-Guided Surgery.Diagnostics (Basel, Switzerland) · 2021Article
- Current state of intraoperative use of near infrared fluorescence for parathyroid identification and preservation.Surgery · 2021Article
- Detecting the Near Infrared Autofluorescence of the Human Parathyroid: Hype or Opportunity?Annals of surgery · 2020Review
- Highly stable folic acid functionalized copper-nanocluster/silica nanoparticles for selective targeting of cancer cells.RSC advances · 2020Article
- Repurposing Molecular Imaging and Sensing for Cancer Image-Guided Surgery.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2020Review
- Anatomical Considerations and Procedure-Specific Aspects Important in Preventing Operative Morbidity during Transanal Total Mesorectal Excision.Clinics in colon and rectal surgery · 2020Review
- Selective imaging of solid tumours via the calcium-dependent high-affinity binding of a cyclic octapeptide to phosphorylated Annexin A2.Nature biomedical engineering · 2020Article
- NaNature communications · 2019Article
- Fluorescence Guidance in Surgical Oncology: Challenges, Opportunities, and Translation.Molecular imaging and biology · 2019Review
- Robotic-assisted stereotactic real-time navigation: initial clinical experience and feasibility for rectal cancer surgery.Techniques in coloproctology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundThe inability to visualize the patient and surgical site directly, limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment.
methodsWe evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared, fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided, tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided, popliteal lymph node resection. Four breast cancer patients received
resultsUsing near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and four pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67 ± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin-embedded section histopathology.
conclusionsThe optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room.
Indexed as
Identifiers
What OpenQuestion holds