ArticlePloS one2017
Human cortical neural correlates of visual fatigue during binocular depth perception: An fNIRS study.
Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Trial
- Association between fusion visual function deficits and myopia in school-aged children: an analysis based on competitive binocular vision screening.BMC ophthalmology · 2026Article
- fNIRS as a biomarker for X-linked neurodevelopmental disorders: leveraging visual processing to assess brain function?Frontiers in neuroscience · 2025Article
- A dual-branch deep learning model based on fNIRS for assessing 3D visual fatigue.Frontiers in neuroscience · 2025Article
- Prefrontal cortex activity during binocular color fusion and rivalry: an fNIRS study.Frontiers in neurology · 2025Article
- Central imaging based on near-infrared functional imaging technology can be useful to plan management in patients with chronic lateral ankle instability.Journal of orthopaedic surgery and research · 2024Article
- An investigation into the correlation between visual performance in simulated complex environments and academic attainment among primary school students.Scientific reports · 2024Article
- Functional Near-Infrared Spectrometry as a Useful Diagnostic Tool for Understanding the Visual System: A Review.Journal of clinical medicine · 2024Review
- Utilizing EEG and fNIRS for the detection of sleep-deprivation-induced fatigue and its inhibition using colored light stimulation.Scientific reports · 2023Article
- Design guidelines for limiting and eliminating virtual reality-induced symptoms and effects at work: a comprehensive, factor-oriented review.Frontiers in psychology · 2023Review
- Effects of Paradigm Color and Screen Brightness on Visual Fatigue in Light Environment of Night Based on Eye Tracker and EEG Acquisition Equipment.Sensors (Basel, Switzerland) · 2022Article
- Network Pharmacology, Molecular Docking, and Molecular Dynamic-Based Investigation on the Mechanism of Compound Chrysanthemum in the Treatment of Asthenopia.Computational and mathematical methods in medicine · 2022Article
- The Influence of Medical Professional Knowledge on Empathy for Pain: Evidence From fNIRS.Frontiers in psychology · 2018Article
- Prefrontal Cortex Oxygenation Evoked by Convergence Load Under Conflicting Stimulus-to-Accommodation and Stimulus-to-Vergence Eye-Movements Measured by NIRS.Frontiers in human neuroscience · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Functional near-infrared spectroscopy (fNIRS) was adopted to investigate the cortical neural correlates of visual fatigue during binocular depth perception for different disparities (from 0.1° to 1.5°). By using a slow event-related paradigm, the oxyhaemoglobin (HbO) responses to fused binocular stimuli presented by the random-dot stereogram (RDS) were recorded over the whole visual dorsal area. To extract from an HbO curve the characteristics that are correlated with subjective experiences of stereopsis and visual fatigue, we proposed a novel method to fit the time-course HbO curve with various response functions which could reflect various processes of binocular depth perception. Our results indicate that the parietal-occipital cortices are spatially correlated with binocular depth perception and that the process of depth perception includes two steps, associated with generating and sustaining stereovision. Visual fatigue is caused mainly by generating stereovision, while the amplitude of the haemodynamic response corresponding to sustaining stereovision is correlated with stereopsis. Combining statistical parameter analysis and the fitted time-course analysis, fNIRS could be a promising method to study visual fatigue and possibly other multi-process neural bases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials