Evidence map›Paper›PMID 28199078›Full record

ArticleInternational braz j urol : official journal of the Brazilian Society of Urology

Anterior six arms prolene mesh for high stage vaginal prolapse: five years follow-up.

Luis Gustavo M de Toledo, André Costa-Matos, Susane Mey Hwang, Raquel Dória Ramos Richetti, Silvia S Carramão, Antônio P F Auge

Open access · diamondAbstract read
In one paragraph

Article in International braz j urol : official journal of the Brazilian Society of Urology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Luis Gustavo M de ToledoFaculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brasil.
André Costa-MatosServiço de Uroginecologia, Maternidade Cachoeirinha, São Paulo, SP, Brasil.
Susane Mey HwangServiço de Uroginecologia, Maternidade Cachoeirinha, São Paulo, SP, Brasil.
Raquel Dória Ramos RichettiServiço de Uroginecologia, Maternidade Cachoeirinha, São Paulo, SP, Brasil.
Silvia S CarramãoFaculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brasil.
Antônio P F AugeFaculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP, Brasil.
Faculdade de Ciências Médicas da Santa Casa de São Paulo · BRNational Institute of Science and Technology for Software Engineering · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn high stage vaginal prolapse, recurrence risk patients, anterior and apical defects need to be addressed in the same procedure. The pre-molded commercial mesh kits are expensive and not always available. Alternative effective and safe treatment ways, with lower costs are desirable.

objectiveTo present long term follow-up of patients treated with a homemade mesh shape to correct high stage prolapses. MATERIALS AND

methodsWe describe prospectively 18 patients with anterior and apical vaginal prolapses, stages III and IV, repaired using this specific design of mesh. All patients were submitted to pre-operative clinical evaluation and urodynamics. Prolapse was classified using the pelvic organ prolapse quantification (POP-Q).

interventionProlapse surgery, using a six arms prolene mesh, through a single anterior vaginal incision. OUTCOME MEASUREMENTS: POP-Q, patients satisfaction, descriptive statistical analysis.

resultsBetween February 2009 and Oct 2010, 18 consecutive women underwent the above-mentioned surgery. Mean age was 68 years. At a mean follow-up of 4 years (5 to 5.8 years), 16 (89%) patients were continent, mean Ba point came from +4.7cm to -2.5cm, mean C point from +2.8cm to -6.6cm and mean Bp point from +1.3 to -1.7cm. There were two (11%) objective failures, but all the patients were considered success subjectively. There were two cases of mesh vaginal extrusion.

conclusionsThe homemade six arms prolene mesh allows concomitant correction of anterior and apical prolapses, through a single anterior vaginal incision, being an effective, safe and affordable treatment option when mesh is needed.

Indexed as

Surgical MeshAgedAged, 80 and overFemaleFollow-Up StudiesHumansMiddle AgedProspective StudiesTime FactorsUrinary IncontinenceUrodynamicsUterine ProlapseVaginaPelvic Organ ProlapseSurgical MeshSurgical Procedures, Operative

Identifiers

PMID28199078
PMCPMC5462145
OpenAlexW2624241534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.