Evidence map›Paper›PMID 28196288›Full record

ArticleMedical physics2017

Clinical adequacy assessment of autocontours for prostate IMRT with meaningful endpoints.

Hamidreza Nourzadeh, William T Watkins, Mahmoud Ahmed, Cheukkai Hui, David Schlesinger, Jeffrey V Siebers

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Hamidreza NourzadehDepartment of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA.
William T WatkinsDepartment of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA.
Mahmoud AhmedDepartment of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA.
Cheukkai HuiDepartment of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA.
David SchlesingerDepartment of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA.
Jeffrey V SiebersDepartment of Radiation Oncology, University of Virginia, Charlottesville, VA, 22908, USA.
University of Virginia · US

Funding

Software Engineering, Treatment Planning, and QAP01CA116602 · NCI · VIRGINIA COMMONWEALTH UNIVERSITY · PI MURPHY, MARTIN J · 2007 to 2011
$10.4M
Comprehensive analysis and mitigation of the clinical effects of delineation and geometric uncertainties in conformal radiation therapyR01CA222216 · NCI · UNIVERSITY OF VIRGINIA · PI SIEBERS, JEFFREY VINCENT · 2018 to 2023
$1.6M
NCI NIH HHS P01 CA116602NCI NIH HHS R01 CA222216
6 · The paper itself

Abstract

purposeTo determine if radiation treatment plans created based on autosegmented (AS) regions-of-interest (ROI)s are clinically equivalent to plans created based on manually segmented ROIs, where equivalence is evaluated using probabilistic dosimetric metrics and probabilistic biological endpoints for prostate IMRT. METHOD AND MATERIALS: Manually drawn contours and autosegmented ROIs were created for 167 CT image sets acquired from 19 prostate patients. Autosegmentation was performed utilizing Pinnacle's Smart Probabilistic Image Contouring Engine. For each CT set, 78 Gy/39 fraction 7-beam IMRT treatment plans with 1 cm CTV-to-PTV margins were created for each of the three contour scenarios; P

resultsFemoral head dose objectives were satisfied in all situations, as well as the maximum dose objectives for all ROIs. Bladder metrics were within the clinical coverage tolerances except D

conclusionsWhen including daily setup variations in prostate IMRT, the dose-volume metric CP, and biological indices of ROIs were approximately equivalent for the plans created based on manually drawn targets and autosegmented OARs in 88% of cases. The accuracy of autosegmented prostates and rectums are impediment to attain statistically equivalent plans created based on manually drawn ROIs.

Indexed as

Endpoint DeterminationHumansImage Processing, Computer-AssistedMaleProbabilityProstatic NeoplasmsRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-Assistedautocontourprostate cancertreatment planninguncertainties in radiation therapy

Identifiers

PMID28196288
PMCPMC10659108
OpenAlexW2587946796

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.