Evidence map›Paper›PMID 28194710›Full record

ArticleClinical orthopaedics and related research2017

Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship Than Other Designs: A Nationwide Cohort of 324,108 Patients.

Sandrine Colas, Assia Allalou, Antoine Poichotte, Philippe Piriou, Rosemary Dray-Spira, Mahmoud Zureik

Open access · hybridAbstract readComparative Study
In one paragraph

Article in Clinical orthopaedics and related research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
7.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 55 citations in OpenAlex.

  1. Article
  2. Do all anatomic stems perform equally at long-term survival? A regional registry-based study on 12,010 total hip arthroplasty implants according to stem length and neck modularity.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2025
    Article
  3. Review
  4. Article
  5. Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2023
    Article
  6. Article
  7. Article
  8. Comparison of single taper and dual taper versions of the same stem design in total hip arthroplasty for primary osteoarthritis.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2023
    Article
  9. Review
  10. Article
  11. Article
  12. Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2020
    Article
  13. Observational
  14. Article
  15. Observational
  16. Article
  17. Modular femoral neck failure after revision of a total hip arthroplasty: a finite element analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2019
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Sandrine ColasFrench National Agency for Medicines and Health Products Safety, Saint-Denis, France. sandrine.colas@ansm.sante.fr.
Assia AllalouFrench National Agency for Medicines and Health Products Safety, Saint-Denis, France.
Antoine PoichotteCentre Hospitalier Loire Vendée Océan, Challans, France.
Philippe PiriouClinique du Parc, Autun, France.
Rosemary Dray-SpiraFrench National Agency for Medicines and Health Products Safety, Saint-Denis, France.
Mahmoud ZureikFrench National Agency for Medicines and Health Products Safety, Saint-Denis, France.
Agence Nationale de Sécurité Sanitaire de l’Alimentation, de l’Environnement et du Travail · FRCentre Val de Loire · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExchangeable neck stems, defined as those with a dual taper (that is, a modular junction between the femoral head and the femoral neck and an additional junction between the neck and the stem body), were introduced in THA to improve restoration of joint biomechanics (restoring anteversion, offset, and limb length) and reduce the risk of dislocation. However exchangeable necks have been reported to result in adverse effects such as stem fractures and acute local tissue reaction. Whether they result in a net improvement to or impairment of reconstructive survivorship remains controversial. QUESTIONS/PURPOSES: (1) To compare the prosthetic survivorship and all-cause revision risk of exchangeable femoral neck THAs versus fixed neck THAs, taking known prosthetic revision risk factors into account; and (2) to compare the cause-specific revision risk of exchangeable femoral neck THAs versus fixed neck THAs, adjusting for known prosthetic risk factors.

methodsUsing French national health-insurance databases, we identified all French patients older than 40 years who underwent primary THA from 2009 through 2012. To ensure accuracy of the data, we considered only beneficiaries of the general insurance scheme (approximately 77% of the population). Characteristics of the prosthesis and the patients receiving an exchangeable femoral neck THA were compared with those receiving a fixed femoral neck THA (defined as femoral stem with only the head being exchangeable). Revision was the event of interest. Followup started on the date the THA was performed, until the patient experienced revision, died, was lost to followup, or until the followup period ended (December 31, 2014), whichever came first. Competing risk THA survivorship was calculated and compared (purpose 1), as were cause-specific Cox regression models (purpose 2). The study cohort included 324,108 individuals with a mean age of 77 years. A total of 24% underwent THA for acute trauma, and 3% of the group received an exchangeable neck THA. During the median 45-month followup (mean, 42 months; minimum, 1 day; maximum, 6 years), 11,968 individuals underwent prosthetic revision.

resultsThe cumulative revision incidence was 6.5% (95% CI, 5.8%-7.3%) for exchangeable neck THAs versus 4.7% (95% CI, 4.6%-4.8%) for fixed neck THAs (p < 0.001). After controlling for potential confounding variables including age, sex, comorbidities, indication for THA, cementation, bearing surface, and the characteristics of the center where the implantation was performed, we found that the exchangeable femoral neck THA was associated with an increased hazard ratio (HR) of revision of 1.26 (95% CI, 1.14-1.38; p < 0.001) compared with the fixed neck THA. When dealing with cause-specific revision, exchangeable neck THAs had a higher incidence of revision for implant failure or periprosthetic fracture, and for mechanical complications; adjusted HRs were, respectively, 1.68 (95% CI, 1.24-2.27; p < 0.001) and 1.27 (95% CI, 1.13-1.43; p < 0.001), for exchangeable neck THAs compared with fixed ones.

conclusionsExchangeable neck THAs had poorer survivorship independent of other prosthetic revision risk factors. Accordingly, expected anatomic and functional benefits should be carefully assessed before choosing this design. LEVEL OF EVIDENCE: Level III, therapeutic study.

Indexed as

AgedAged, 80 and overArthroplasty, Replacement, HipDatabases, FactualFemaleFemur NeckFollow-Up StudiesHip ProsthesisHumansMaleMiddle AgedPeriprosthetic FracturesPostoperative ComplicationsProportional Hazards ModelsProsthesis DesignProsthesis Failure

Identifiers

PMID28194710
PMCPMC5498370
OpenAlexW2588665208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.