Evidence map›Paper›PMID 28191626›Full record

SynthesisThe Cochrane database of systematic reviews2017

Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being.

Ruth Martis, Ova Emilia, Detty S Nurdiati, Julie Brown

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed, 5 pooled it
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 5 syntheses or guidelines pooled it, 40 citations in OpenAlex.

  1. Pooled it
  2. Effectiveness of intrapartum fetal surveillance to improve maternal and neonatal outcomes: a systematic review and network meta-analysis.CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2021
    Pooled it
  3. Systematic review of Doppler for detecting intrapartum fetal heart abnormalities and measuring perinatal mortality in low- and middle-income countries.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2020
    Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Trial
  8. Tools or culture? Human factors, not technology, drive cesarean section rates for suspected fetal distress.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026
    Article
  9. Review
  10. Article
  11. Article
  12. Antenatal Noninvasive Fetal Electrocardiography: A Literature Review.Maternal-fetal medicine (Wolters Kluwer Health, Inc.) · 2024
    Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Delphi consensus statement on intrapartum fetal monitoring in low-resource settings.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Ruth MartisLiggins Institute, The University of Auckland, Park Road, Grafton, Auckland, New Zealand, 1142.
Ova EmiliaDepartment of Obstetrics and Gynaecology, Faculty of Medicine, Universitas Gadjah Mada, Jl. Farmako, Sekip, Yogyakarta, Daerah Istimewa Yogyakarta, Indonesia, 55281.
Detty S NurdiatiDepartment of Obstetrics and Gynaecology, Faculty of Medicine, Universitas Gadjah Mada, Jl. Farmako, Sekip, Yogyakarta, Daerah Istimewa Yogyakarta, Indonesia, 55281.
Julie BrownLiggins Institute, The University of Auckland, Park Road, Grafton, Auckland, New Zealand, 1142.
Universitas Gadjah Mada · IDUniversity of Auckland · NZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe goal of fetal monitoring in labour is the early detection of a hypoxic baby. There are a variety of tools and methods available for intermittent auscultation (IA) of the fetal heart rate (FHR). Low- and middle-income countries usually have only access to a Pinard/Laënnec or the use of a hand-held Doppler device. Currently, there is no robust evidence to guide clinical practice on the most effective IA tool to use, timing intervals and length of listening to the fetal heart for women during established labour.

objectivesTo evaluate the effectiveness of different tools for IA of the fetal heart rate during labour including frequency and duration of auscultation. SEARCH

methodsWe searched the Cochrane Pregnancy and Childbirth Group's Trials Register (19 September 2016), contacted experts and searched reference lists of retrieved articles. SELECTION CRITERIA: All published and unpublished randomised controlled trials (RCTs) or cluster-RCTs comparing different tools and methods used for intermittent fetal auscultation during labour for fetal and maternal well-being. Quasi-RCTs, and cross-over designs were not eligible for inclusion. DATA COLLECTION AND ANALYSIS: All review authors independently assessed eligibility, extracted data and assessed risk of bias for each trial. Data were checked for accuracy. MAIN

resultsWe included three studies (6241 women and 6241 babies), but only two studies are included in the meta-analyses (3242 women and 3242 babies). Both were judged as high risk for performance bias due to the inability to blind the participants and healthcare providers to the interventions. Evidence was graded as moderate to very low quality; the main reasons for downgrading were study design limitations and imprecision of effect estimates. Intermittent Electronic Fetal Monitoring (EFM) using Cardiotocography (CTG) with routine Pinard (one trial)There was no clear difference between groups in low Apgar scores at five minutes (reported as < six at five minutes after birth) (risk ratio (RR) 0.66, 95% confidence interval (CI) 0.24 to 1.83, 633 babies, very low-quality evidence). There were no clear differences for perinatal mortality (RR 0.88, 95% CI 0.34 to 2.25; 633 infants, very low-quality evidence). Neonatal seizures were reduced in the EFM group (RR 0.05, 95% CI 0.00 to 0.89; 633 infants, very low-quality evidence). Other important infant outcomes were not reported: mortality or serious morbidity (composite outcome), cerebral palsy or neurosensory disability. For maternal outcomes, women allocated to intermittent electronic fetal monitoring (EFM) (CTG) had higher rates of caesarean section for fetal distress (RR 2.92, 95% CI 1.78 to 4.80, 633 women, moderate-quality evidence) compared with women allocated to routine Pinard. There was no clear difference between groups in instrumental vaginal births (RR 1.46, 95% CI 0.86 to 2.49, low-quality evidence). Other outcomes were not reported (maternal mortality, instrumental vaginal birth for fetal distress and or acidosis, analgesia in labour, mobility or restriction during labour, and postnatal depression). Doppler ultrasonography with routine Pinard (two trials)There was no clear difference between groups in Apgar scores < seven at five minutes after birth (reported as < six in one of the trials) (average RR 0.76, 95% CI 0.20 to 2.87; two trials, 2598 babies, I AUTHORS'

conclusionsUsing a hand-held (battery and wind-up) Doppler and intermittent CTG with an abdominal transducer without paper tracing for IA in labour was associated with an increase in caesarean sections due to fetal distress. There was no clear difference in neonatal outcomes (low Apgar scores at five minutes after birth, neonatal seizures or perinatal mortality). Long-term outcomes for the baby (including neurodevelopmental disability and cerebral palsy) were not reported. The quality of the evidence was assessed as moderate to very low and several important outcomes were not reported which means that uncertainty remains regarding the use of IA of FHR in labour.As intermittent CTG and Doppler were associated with higher rates of caesarean sections compared with routine Pinard monitoring, women, health practitioners and policy makers need to consider these results in the absence of evidence of short- and long-term benefits for the mother or baby.Large high-quality randomised trials, particularly in low-income settings, are needed. Trials should assess both short- and long-term health outcomes, comparing different monitoring tools and timing for IA.

Indexed as

Heart Rate, FetalLabor, ObstetricAuscultationCardiotocographyCesarean SectionFemaleFetal DistressHumansInfant, NewbornInfant, Newborn, DiseasesPerinatal MortalityPregnancySeizuresUltrasonography, Doppler

Identifiers

PMID28191626
PMCPMC6464556
OpenAlexW2129204616

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.