ArticleInternational journal of computer assisted radiology and surgery2017
Application of computer-aided design and 3D-printed navigation template in Locking Compression Pediatric Hip Plate
Article in International journal of computer assisted radiology and surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05245617 (A Single Center Post-market Clinical Follow up), which is not on this map. Cited by 38 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Single Center Post-market Clinical Follow up (PMCF) Observational Study Evaluating the Clinical Performance and the Safety Profile of the JuniOrtho™ Plating System™ (JPS) for the Treatment of Congenital Deformities and Fractures in Lower Limb of Pediatric and Adult Patients
Who cites it
38 citing papers in PubMed, 1 synthesis or guideline pooled it, 47 citations in OpenAlex.
- Three-dimensional printing in medicine: a systematic review of pediatric applications.Pediatric research · 2021Pooled it
- Efficacy Evaluation of 3D Navigational Template for Salter Osteotomy of DDH in Children.BioMed research international · 2021Trial
- Clinical application of individualized 3D-printed navigation template to children with cubitus varus deformity.Journal of orthopaedic surgery and research · 2020Trial
- Development of a new operative 3D printed template-cranioplasty-concept for performing craniotomy in the posterior cranial fossa and validation of the system using a 3D printed simulation model: a preclinical feasibility study.3D printing in medicine · 2026Article
- A novel computer-assisted drill guide template for guided correction of genu varum.BMC musculoskeletal disorders · 2026Article
- Patient-specific proximal femoral plate combined with a modular 3D-printed osteotomy guide system in children with developmental dysplasia of the hip: a retrospective comparative study.Frontiers in public health · 2026Article
- MRI-CT fusion-based digital true hip reconstruction in pediatric developmental dysplasia of the hip: a preliminary feasibility report.Frontiers in surgery · 2026Article
- 3D-printed navigation-guided FNS-CCS fixation reduces complications in young adults with comminuted femoral neck fractures: a retrospective cohort study.BMC musculoskeletal disorders · 2025Article
- Treatment of benign lesions of the proximal femur in young pediatric patients using adult 3.5 mm proximal humerus locking plates.Frontiers in oncology · 2025Article
- In Situ Fixation and Intertrochanteric Osteotomy for Severe Slipped Capital Femoral Epiphysis Following Femoral Neck Fracture: A Case Report with Application of Virtual Surgical Planning and 3D-Printed Patient-Specific Instruments.Journal of personalized medicine · 2025Article
- Three-dimensional-printing-guided preoperative planning of upper and lower extremity pediatric orthopedic surgeries: A systematic review of surgical outcomes.Journal of children's orthopaedics · 2024Review
- 3D-printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor.Orthopaedic surgery · 2024Article
- Clinical Applications of "In-Hospital" 3D Printing in Hip Surgery: A Systematic Narrative Review.Journal of clinical medicine · 2024Review
- Design and application of a novel 3D printing digital navigation template for cubitus varus deformity in children.Frontiers in pediatrics · 2024Article
- Virtual Surgical Planning and Patient-Specific Instruments for Correcting Lower Limb Deformities in Pediatric Patients: Preliminary Results from the In-Office 3D Printing Point of Care.Journal of personalized medicine · 2023Article
- Minimally invasive retrieval of intramedullary broken guidewire in distal tibia: An innovative technique.Trauma case reports · 2023Article
- Application of the Locking Compression Pediatric Hip Plate™ in children with proximal femoral tumors.Journal of orthopaedic surgery and research · 2022Article
- Performance of Tönnis triple osteotomy in older children with developmental dysplasia of the hip (DDH) assisted by a 3D printing navigation template.BMC musculoskeletal disorders · 2022Article
- Clinical applications and prospects of 3D printing guide templates in orthopaedics.Journal of orthopaedic translation · 2022Review
- Visualized simulative surgery in preoperative planning for proximal femoral varus osteotomy of DDH.BMC musculoskeletal disorders · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo investigate the feasibility and accuracy of a drill template based on computer-aided design (CAD) and 3D printing technology for the placement of screws in Locking Compression Pediatric Hip Plate (LCP-PHP).
methodsLCP-PHP was used in 11 children [5 with femoral neck fracture and 6 with development dysplasia of hip (DDH)]. Using the CT data, the proximal femur model was created by a 3D printer. Fracture reduction and the placement of the screw in the femoral neck and the LCP-PHP were simulated by the computer. The navigation template was designed by the software to match the proximal femur. After the feasibility of the 3D model operation was demonstrated before the operation, the guide pins and the screws were inserted with the help of the navigate template in the operation.
resultsDuring surgery, the navigation template for each case was matched to the bony markers of the proximal femur. With the help of the template, in femoral neck fracture cases, three screws could be accurately inserted into the femoral neck to implant the LCP-PHP and stabilize the fracture. The template for DDH includes all operation parameters and steps for proximal femoral varus rotation and shortening osteotomy, which made the surgery much easier to perform. Radiographs taken after surgery showed that the postoperative results closely corresponded to the preoperative computer simulation. The average time taken for LCP-PHP placement was 26.5 min; radiography was used during surgery only for an average of 6.0 times. Postoperative radiographs showed good results.
conclusionWith the use of CAD and 3D printing technology, accurate placement of individualized navigation template of LCP-PHP can be achieved. This technology can reduce intraoperative damage to the femoral neck epiphysis, decrease operation time, reduce intraoperative hemorrhage, and decrease radiation exposure to patients and personnel during the surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.