ArticleJournal of visualized experiments : JoVE2017
Multi-step Variable Height Photolithography for Valved Multilayer Microfluidic Devices.
Article in Journal of visualized experiments : JoVE, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Dynamic microphysiological system chip platform for high-throughput, customizable, and multi-dimensional drug screening.Bioactive materials · 2024Article
- Advances in paper-based electrochemical immunosensors: review of fabrication strategies and biomedical applications.Royal Society open science · 2023Review
- Microfluidic encapsulation of photosynthetic cyanobacteria in hydrogel microparticles augments oxygen delivery to rescue ischemic myocardium.Journal of bioscience and bioengineering · 2023Article
- Addressable microfluidics technology for non-sacrificial analysis of biomaterial implantsBiomicrofluidics · 2023Article
- Controlling Particle Fraction in Microporous Annealed Particle Scaffolds for 3D Cell Culture.Journal of visualized experiments : JoVE · 2022Article
- Thermally-actuated microfluidic membrane valve for point-of-care applications.Microsystems & nanoengineering · 2021Article
- Double Emulsion Picoreactors for High-Throughput Single-Cell Encapsulation and Phenotyping via FACS.Analytical chemistry · 2020Article
- micrIO: an open-source autosampler and fraction collector for automated microfluidic input-output.Lab on a chip · 2020Article
- Live imaging of Aiptasia larvae, a model system for coral and anemone bleaching, using a simple microfluidic device.Scientific reports · 2019Article
- Enzyme-Based Electrochemical Biosensors for Microfluidic Platforms to Detect Pharmaceutical Residues in Wastewater.Biosensors · 2019Review
- One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes.Journal of visualized experiments : JoVE · 2018Article
- An Open-Source, Programmable Pneumatic Setup for Operation and Automated Control of Single- and Multi-Layer Microfluidic Devices.HardwareX · 2018Article
- Controller for microfluidic large-scale integration.HardwareX · 2018Article
- Using a Microfluidics Device for Mechanical Stimulation and High Resolution Imaging of C. elegans.Journal of visualized experiments : JoVE · 2018Article
- BET-seq: Binding energy topographies revealed by microfluidics and high-throughput sequencing.Methods in cell biology · 2018Article
- Microstructured Devices for Optimized Microinjection and Imaging of Zebrafish Larvae.Journal of visualized experiments : JoVE · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Microfluidic systems have enabled powerful new approaches to high-throughput biochemical and biological analysis. However, there remains a barrier to entry for non-specialists who would benefit greatly from the ability to develop their own microfluidic devices to address research questions. Particularly lacking has been the open dissemination of protocols related to photolithography, a key step in the development of a replica mold for the manufacture of polydimethylsiloxane (PDMS) devices. While the fabrication of single height silicon masters has been explored extensively in literature, fabrication steps for more complicated photolithography features necessary for many interesting device functionalities (such as feature rounding to make valve structures, multi-height single-mold patterning, or high aspect ratio definition) are often not explicitly outlined. Here, we provide a complete protocol for making multilayer microfluidic devices with valves and complex multi-height geometries, tunable for any application. These fabrication procedures are presented in the context of a microfluidic hydrogel bead synthesizer and demonstrate the production of droplets containing polyethylene glycol (PEG diacrylate) and a photoinitiator that can be polymerized into solid beads. This protocol and accompanying discussion provide a foundation of design principles and fabrication methods that enables development of a wide variety of microfluidic devices. The details included here should allow non-specialists to design and fabricate novel devices, thereby bringing a host of recently developed technologies to their most exciting applications in biological laboratories.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.