Evidence map›Paper›PMID 28187249›Full record

ArticleNMR in biomedicine2017

Parallel transmission RF pulse design with strict temperature constraints.

Cem M Deniz, Giuseppe Carluccio, Christopher Collins

Abstract read
In one paragraph

Article in NMR in biomedicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Parallel Transmission for Ultrahigh Field MRI.Topics in magnetic resonance imaging : TMRI · 2019
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Cem M DenizCenter for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York, NY, USA.ORCID http://orcid.org/0000-0001-8809-5945
Giuseppe CarluccioCenter for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York, NY, USA.
Christopher CollinsCenter for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York, NY, USA.

Funding

TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Hersh Chandarana · 2014 to 2026
$19.3M
RF Technology Innovation for Advancing High Field MR.R01EB011551 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI COLLINS, CHRISTOPHER M · 2011 to 2014
$2.7M
NIBIB NIH HHS P41 EB017183NIBIB NIH HHS R01 EB011551
6 · The paper itself

Abstract

RF safety in parallel transmission (pTx) is generally ensured by imposing specific absorption rate (SAR) limits during pTx RF pulse design. There is increasing interest in using temperature to ensure safety in MRI. In this work, we present a local temperature correlation matrix formalism and apply it to impose strict constraints on maximum absolute temperature in pTx RF pulse design for head and hip regions. Electromagnetic field simulations were performed on the head and hip of virtual body models. Temperature correlation matrices were calculated for four different exposure durations ranging between 6 and 24 min using simulated fields and body-specific constants. Parallel transmission RF pulses were designed using either SAR or temperature constraints, and compared with each other and unconstrained RF pulse design in terms of excitation fidelity and safety. The use of temperature correlation matrices resulted in better excitation fidelity compared with the use of SAR in parallel transmission RF pulse design (for the 6 min exposure period, 8.8% versus 21.0% for the head and 28.0% versus 32.2% for the hip region). As RF exposure duration increases (from 6 min to 24 min), the benefit of using temperature correlation matrices on RF pulse design diminishes. However, the safety of the subject is always guaranteed (the maximum temperature was equal to 39°C). This trend was observed in both head and hip regions, where the perfusion rates are very different.

Indexed as

Equipment SafetyBody TemperatureBrainComputer-Aided DesignComputer SimulationDose-Response Relationship, RadiationEquipment DesignEquipment Failure AnalysisHumansMagnetic FieldsMagnetic Resonance ImagingModels, NeurologicalPatient SafetyPhantoms, ImagingRadiation DosageRadio Wavesparallel transmissionRF pulse designtemperature constraintstemperature correlation matrices

Identifiers

PMID28187249
PMCPMC5456413

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.