ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)

Fiber Bundle Design for an Integrated Wearable Artificial Lung.

Shalv P Madhani, Brian J Frankowski, William J Federspiel

Abstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Improvement of a Mathematical Model to Predict COBioengineering (Basel, Switzerland) · 2022
    Article
  2. In Vivo 5 Day Animal Studies of a Compact, Wearable Pumping Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2019
    Article
  3. Bench Validation of a Compact Low-Flow COIntensive care medicine experimental · 2018
    Article
  4. Article
  5. In Vitro Characterization of the Pittsburgh Pediatric Ambulatory Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Shalv P MadhaniFrom the *McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania; †Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania; ‡Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania; and §Department of Critical Care Medicine, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Brian J Frankowski
William J Federspiel

Funding

Multiscale Model of Thrombosis in Artificial CirculationR01HL089456 · NHLBI · CORNELL UNIVERSITY · PI ANTAKI, JAMES F., BUTCHER, JONATHAN TALBOT · 2009 to 2024
$8.5M
Paracorporeal Ambulatory Assist LungR01HL117637 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI ANTAKI, JAMES F., DCUNHA, JONATHAN · 2013 to 2017
$3.5M
NHLBI NIH HHS R01 HL089456NHLBI NIH HHS R01 HL117637
6 · The paper itself

Abstract

Mechanical ventilation (MV) and extracorporeal membrane oxygenation (ECMO) are the only viable treatment options for lung failure patients at the end-stage, including acute respiratory distress syndrome (ARDS) and chronic obstructive pulmonary disease (COPD). These treatments, however, are associated with high morbidity and mortality because of long wait times for lung transplant. Contemporary clinical literature has shown ambulation improves post-transplant outcomes in lung failure patients. Given this, we are developing the Pittsburgh Ambulatory Assist Lung (PAAL), a truly wearable artificial lung that allows for ambulation. In this study, we targeted 180 ml/min oxygenation and determined the form factor for a hollow fiber membrane (HFM) bundle for the PAAL. Based on a previously published mass transfer correlation, we modeled oxygenation efficiency as a function of fiber bundle diameter. Three benchmark fiber bundles were fabricated to validate the model through in vitro blood gas exchange at blood flow rates from 1 to 4 L/min according to ASTM standards. We used the model to determine a final design, which was characterized in vitro through a gas exchange as well as a hemolysis study at 3.5 L/min. The percent difference between model predictions and experiment for the benchmark bundles ranged from 3% to 17.5% at the flow rates tested. Using the model, we predicted a 1.75 in diameter bundle with 0.65 m surface area would produce 180 ml/min at 3.5 L/min blood flow rate. The oxygenation efficiency was 278 ml/min/m and the Normalized Index of Hemolysis (NIH) was less than 0.05 g/100 L. Future work involves integrating this bundle into the PAAL for which an experimental prototype is under development in our laboratory.

Indexed as

Artificial OrgansLungExtracorporeal Membrane OxygenationHumansOxygenPulmonary Disease, Chronic ObstructiveRespiration, ArtificialRespiratory Distress SyndromeRespiratory InsufficiencyOxygen

Identifiers

PMID28187049
PMCPMC6051544

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.