ArticleJournal of orthopaedic surgery and research2017
Percutaneous internal fixation with Y-STRUT® device to prevent both osteoporotic and pathological hip fractures: a prospective pilot study.
Article in Journal of orthopaedic surgery and research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03580434 (National, Multicentre, Pilot Study, to Evaluate Safety and Performance of the V-STRUT© Transpedicular Vertebral System Indicated for Vertebral Compression Fracture Treatment), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
National, Multicentre, Pilot Study, to Evaluate Safety and Performance of the V-STRUT© Transpedicular Vertebral System Indicated for Vertebral Compression Fracture Treatment
Who cites it
9 citing papers in PubMed, 23 citations in OpenAlex.
- An analysis of different reconstruction techniques for the radius: a finite element analysis.Biomechanics and modeling in mechanobiology · 2026Article
- Prophylactic fixation in elderly fractures: Preventive breakthrough or unnecessary intervention?World journal of orthopedics · 2025Review
- Different polymethylmethacrylate (PMMA) reinforcement strategies for long bone osteoplasty procedures: a controlled laboratory comparison using the 4-point bending test.BMC musculoskeletal disorders · 2024Article
- Percutaneous-Reinforced Osteoplasty: A Review of Emerging Treatment Strategies for Bone Interventions.Journal of clinical medicine · 2022Review
- Musculoskeletal interventional oncology: current and future practices.The British journal of radiology · 2020Review
- Hip Fracture Prevention in Osteoporotic Elderly and Cancer Patients: An On-Line French Survey Evaluating Current Needs.Medicina (Kaunas, Lithuania) · 2020Article
- Biomechanical effects of osteoplasty with or without Kirschner wire augmentation on long bone diaphyses undergoing bending stress: implications for percutaneous imaging-guided consolidation in cancer patients.European radiology experimental · 2019Article
- Percutaneous osteoplasty for extraspinal metastases.Journal of interventional medicine · 2018Review
- PRELIMINARY MECHANICAL TEST OF PROXIMAL FEMUR REINFORCEMENT WITH CEMENTED X-SHAPED PMMA.Acta ortopedica brasileira · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe studied Y-STRUT® (Hyprevention, France), a new percutaneous internal fixation device, in combination with bone cementoplasty to prevent hip fracture.
methodsBetween February 2013 and February 2015, a total of 16 femoral necks in 4 osteoporotic and 12 oncologic patients have been considered for prophylactic consolidation in this prospective multicentre pilot study involving 4 different hospitals. These consolidations were performed percutaneously under fluoroscopic guidance using Y-STRUT®, a dedicated internal fixation device. For osteoporotic patients, orthopaedic surgeons performed the prophylactic consolidations immediately after surgical treatment of a hip fracture (same anaesthesia) in the opposite side. For oncologic patients, without current hip fracture but considered at risk (Mirels score ≥8), interventional radiologists performed the procedures. We report the preliminary results of feasibility, safety and tolerance of these preventive consolidations using Y-STRUT®.
resultsFour patients (mean 83 years old) had prophylactic consolidation because of a severe osteoporosis (mean T-score -3.30) resulting in first hip fractures. Ten patients (mean 61 years old) were treated because of impending pathological fractures (mean Mirels score 9) related to femoral neck osteolytic metastases. All the procedures were performed with success. Wound healing was achieved in all cases with no access site complication. Radiographic exams performed at 3 months follow-up revealed that Y-STRUT® was well integrated in the bone. For the osteoporotic cohort, mean pain was 0.9 ± 0.7 at 3 weeks. For the oncologic cohort, it decreases from 3.6 ± 2.9 at baseline to 2.4 ± 0.9 at 2 months.
conclusionsPreliminary results demonstrate the feasibility and safety of Y-STRUT® implantation as well as the tolerance of the device.