Evidence map›Paper›PMID 28183325›Full record

ArticleJournal of orthopaedic surgery and research2017

Percutaneous internal fixation with Y-STRUT® device to prevent both osteoporotic and pathological hip fractures: a prospective pilot study.

François H Cornelis, Lambros Tselikas, Thibault Carteret, Bruno Lapuyade, Thierry De Baere, Jean Charles Le Huec, Frédéric Deschamps

Registry-linked trialOpen access · goldAbstract readMulticenter Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03580434 (National, Multicentre, Pilot Study, to Evaluate Safety and Performance of the V-STRUT© Transpedicular Vertebral System Indicated for Vertebral Compression Fracture Treatment), which is not on this map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03580434 nacompletednot on this mapstarted 2019, after this paper: background citation

National, Multicentre, Pilot Study, to Evaluate Safety and Performance of the V-STRUT© Transpedicular Vertebral System Indicated for Vertebral Compression Fracture Treatment

TypeinterventionalSponsorHypreventionRan2019 to 2022Enrolled9ConditionsVertebral Compression FractureArmsV-STRUT
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Percutaneous osteoplasty for extraspinal metastases.Journal of interventional medicine · 2018
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

François H CornelisPellegrin Hospital, CHU Bordeaux, Bordeaux, France. cornelisfrancois@gmail.com.
Lambros TselikasGustave Roussy Cancer Campus Grand Paris, Villejuif, France.
Thibault CarteretHaut-Leveque Hospital, CHU Bordeaux, Bordeaux, France.
Bruno LapuyadeHaut-Leveque Hospital, CHU Bordeaux, Bordeaux, France.
Thierry De BaereGustave Roussy Cancer Campus Grand Paris, Villejuif, France.
Jean Charles Le HuecPellegrin Hospital, CHU Bordeaux, Bordeaux, France.
Frédéric DeschampsGustave Roussy Cancer Campus Grand Paris, Villejuif, France.
Institut Gustave Roussy · FRHôpital Cardiologique du Haut-Lévêque · FRHôpital Pellegrin · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe studied Y-STRUT® (Hyprevention, France), a new percutaneous internal fixation device, in combination with bone cementoplasty to prevent hip fracture.

methodsBetween February 2013 and February 2015, a total of 16 femoral necks in 4 osteoporotic and 12 oncologic patients have been considered for prophylactic consolidation in this prospective multicentre pilot study involving 4 different hospitals. These consolidations were performed percutaneously under fluoroscopic guidance using Y-STRUT®, a dedicated internal fixation device. For osteoporotic patients, orthopaedic surgeons performed the prophylactic consolidations immediately after surgical treatment of a hip fracture (same anaesthesia) in the opposite side. For oncologic patients, without current hip fracture but considered at risk (Mirels score ≥8), interventional radiologists performed the procedures. We report the preliminary results of feasibility, safety and tolerance of these preventive consolidations using Y-STRUT®.

resultsFour patients (mean 83 years old) had prophylactic consolidation because of a severe osteoporosis (mean T-score -3.30) resulting in first hip fractures. Ten patients (mean 61 years old) were treated because of impending pathological fractures (mean Mirels score 9) related to femoral neck osteolytic metastases. All the procedures were performed with success. Wound healing was achieved in all cases with no access site complication. Radiographic exams performed at 3 months follow-up revealed that Y-STRUT® was well integrated in the bone. For the osteoporotic cohort, mean pain was 0.9 ± 0.7 at 3 weeks. For the oncologic cohort, it decreases from 3.6 ± 2.9 at baseline to 2.4 ± 0.9 at 2 months.

conclusionsPreliminary results demonstrate the feasibility and safety of Y-STRUT® implantation as well as the tolerance of the device.

Indexed as

AgedAged, 80 and overCementoplastyCohort StudiesFemaleFollow-Up StudiesFracture Fixation, InternalHip FracturesHumansInternal FixatorsMaleMiddle AgedOsteoporosisPilot ProjectsProspective StudiesBiomechanical reinforcementBone metastasesOsteoporosisPathological hip fractureProphylactic consolidationProximal femur

Identifiers

PMID28183325
PMCPMC5301413
OpenAlexW2586397290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.