Evidence map›Paper›PMID 28181011›Full record

ArticleHeart and vessels2017

Intracardiac impedance after cardiac resynchronization therapy is a novel predictor for worsening of heart failure.

Hitoshi Suzuki, Minoru Nodera, Masashi Kamioka, Takashi Kaneshiro, Yoshiyuki Kamiyama, Yasuchika Takeishi

Abstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Biotronik Implantable Cardioverter Defibrillator for Measurement of Intrathoracic Impedance: A Report of Two Cases.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2024
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Hitoshi SuzukiDepartment of Arrhythmia and Cardiac Pacing, Fukushima Medical University, 1 Hikarigaoka, Fukushima, 960-1295, Japan. shitoshi@fmu.ac.jp.
Minoru NoderaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Masashi KamiokaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Takashi KaneshiroDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Yoshiyuki KamiyamaDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Yasuchika TakeishiDepartment of Cardiovascular Medicine, Fukushima Medical University, Fukushima, Japan.
Fukushima Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intrathoracic impedance measured by cardiac resynchronization therapy (CRT) varies because several factors other than pulmonary congestion may affect this parameter. Therefore, we hypothesized that changes in intracardiac impedance between the right and left ventricular leads would be more accurate to identify worsening heart failure in patients with CRT. The study enrolled 21 patients with CRT defibrillator (15 males, 70 ± 12 years). During the follow-up period (12 ± 7 months), the subjects experienced 37 fluid index threshold (60 ohm-days) crossing events. These events were divided into two groups whether hospitalization due to worsening heart failure was required (group-H, n = 14) or not (group-NH, n = 23). Based on the intracardiac impedance at the beginning of increasing fluid index (BI) and the crossing of 60 ohm-days (CI), the rate of impedance change (BI-CI/BI) was estimated. Then, the time elapsed from BI to CI (T) was evaluated. We calculated the rate of intracardiac impedance change per day (BI-CI/BI × T) in each group. The rate of intrathoracic impedance change per day was also determined using the same method. The median rate of intracardiac impedance change per day was 0.27 (IQR 0.22-0.54) %/day in group-H, and 0 (IQR 0-0.08) %/day in group-NH with a significant difference (P < 0.0001), whereas the rate of intrathoracic impedance change per day was similar between the two groups. By receiver operating characteristic curve for identification of hospitalization due to worsening heart failure, the best cutoff value of the rate of intracardiac impedance change per day was 0.20%/day (sensitivity 92%, specificity 88%, and AUC 0.98). In contrast, the best cutoff value of the rate of intrathoracic impedance change per day was 0.19%/day (sensitivity 86%, specificity 43%, and AUC 0.68). These results suggest that increased rate of change of decreasing intracardiac impedance measured by CRT is a novel useful predictor for worsening heart failure.

Indexed as

Defibrillators, ImplantableMonitoring, PhysiologicAgedCardiac Resynchronization TherapyCardiography, ImpedanceDisease ProgressionElectric ImpedanceFemaleFollow-Up StudiesHeart FailureHumansMalePrognosisReproducibility of ResultsStroke VolumeTime FactorsCardiac resynchronization therapyHeart failureIntracaridiac impedanceIntrathoracic impedance

Identifiers

PMID28181011
OpenAlexW2587677493

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.