Evidence map›Paper›PMID 28176255›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2018

Partial volume correction for improved PET quantification in

Jacobo Cal-Gonzalez, Xiang Li, Daniel Heber, Ivo Rausch, Stephen C Moore, Klaus Schäfers, Marcus Hacker, Thomas Beyer

Open access · hybridAbstract read
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
6.0field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Longitudinal analysis of atherosclerotic plaques evolution: anJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  5. Accuracy of PET quantification in [Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  6. Assessment of different quantification metrics of [Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  7. Iterative reconstruction incorporating background correction improves quantification of [Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  8. Fluorine-18 fluorodeoxyglucose positron emission tomography-based textural features for prediction of event prone carotid atherosclerotic plaques.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  9. Optimizing arterialJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  10. Clinical implications ofJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  11. Vulnerable plaque imaging usingThe British journal of radiology · 2020
    Review
  12. PET-derived bone information from 18F-sodium fluoride: A perfect match for whole-body PET/MR attenuation correction?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  13. Comparison of Correction Techniques for the Spill in Effect in Emission Tomography.IEEE transactions on radiation and plasma medical sciences · 2020
    Article
  14. Atherosclerosis imaging withEuropean journal of nuclear medicine and molecular imaging · 2020
    Review
  15. Analytical quantification of aortic valve 18F-sodium fluoride PET uptake.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  16. Coronary artery 18F-NaF PET analysis with the use of an elastic motion correction software.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  17. Review
  18. Review
  19. Hype or HopeCirculation. Cardiovascular imaging · 2019
    Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 3 countries.

Jacobo Cal-GonzalezCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, General Hospital Vienna, Waehringer Guertel 18-20/4L, 1090, Vienna, Austria. jacobo.calgonzalez@meduniwien.ac.at.
Xiang LiDivision of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
Daniel HeberDivision of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
Ivo RauschCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, General Hospital Vienna, Waehringer Guertel 18-20/4L, 1090, Vienna, Austria.
Stephen C MooreDivision of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women's Hospital, Boston, MA, USA.
Klaus SchäfersEuropean Institute for Molecular Imaging, University of Münster, Münster, Germany.
Marcus HackerDivision of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
Thomas BeyerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, General Hospital Vienna, Waehringer Guertel 18-20/4L, 1090, Vienna, Austria.
Medical University of Vienna · ATVienna General Hospital · ATBrigham and Women's Hospital · USUniversity of Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate quantification of plaque imaging using

methodsPVC of PET data was implemented by the use of a local projection (LP) method. LP-based PVC was evaluated with an image quality (NEMA) and with a thorax phantom with "plaque-type" lesions of 18-36 mL. The validated PVC method was then applied to a cohort of 17 patients, each with at least one plaque in the carotid or ascending aortic arteries. In total, 51 calcified (HU > 110) and 16 non-calcified plaque lesions (HU < 110) were analyzed. The lesion-to-background ratio (LBR) and the relative change of LBR (ΔLBR) were measured on PET.

resultsFollowing PVC, LBR of the spheres (NEMA phantom) was within 10% of the original values. LBR of the thoracic lesions increased by 155% to 440% when the LP-PVC method was applied to the PET images. In patients, PVC increased the LBR in both calcified [mean = 78% (-8% to 227%)] and non-calcified plaques [mean = 41%, (-9%-104%)].

conclusionsPVC helps to improve LBR of plaque-type lesions in both phantom studies and clinical patients. Better results were obtained when the PVC method was applied to images reconstructed with point spread function modeling.

Indexed as

RadiopharmaceuticalsAdultAgedCoronary Artery DiseaseFemaleFluorine RadioisotopesHumansMaleMiddle AgedPhantoms, ImagingPlaque, AtheroscleroticPositron-Emission TomographySodium FluorideFluorine-18Fluorine RadioisotopesRadiopharmaceuticalsSodium Fluoride18F-fluoridepartial volume correctionPET/CT imaging of atherosclerotic plaque

Identifiers

PMID28176255
PMCPMC6153866
OpenAlexW2587039906

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.