Observational studyCritical care medicine2017
Bedside Glucose Monitoring-Is it Safe? A New, Regulatory-Compliant Risk Assessment Evaluation Protocol in Critically Ill Patient Care Settings.
Observational study in Critical care medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 58 citations in OpenAlex.
- Lost in Transcription: Frequency of Inaccurate Manually Documented Point-of-Care Blood Glucose and Ketone Measures in Hospital.Endocrinology, diabetes & metabolism · 2026Article
- 16. Diabetes Care in the Hospital: Standards of Care in Diabetes-2026.Diabetes care · 2026Review
- 16. Diabetes Care in the Hospital: Standards of Care in Diabetes-2025.Diabetes care · 2025Review
- Glucose measurements with accu check inform II versus hexokinase plasma method during surgery under general anesthesia, an observational cohort study.Journal of clinical monitoring and computing · 2024Observational
- 16. Diabetes Care in the Hospital: Standards of Care in Diabetes-2024.Diabetes care · 2024Review
- 16. Diabetes Care in the Hospital: Standards of Care in Diabetes-2023.Diabetes care · 2023Review
- Comparison of Accu Chek Inform II point-of-care test blood glucose meter with Hexokinase Plasma method for a diabetes mellitus population during surgery under general anesthesia.Journal of clinical monitoring and computing · 2022Article
- Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes.Diabetes, metabolic syndrome and obesity : targets and therapy · 2022Article
- Comparison of Accuracy Guidelines for Hospital Glucose Meters.Journal of diabetes science and technology · 2020Review
- Accuracy of Blood Glucose Measurement and Blood Glucose Targets.Journal of diabetes science and technology · 2020Review
- Evaluation of Precision and Bias Specifications Required to Achieve the 2018 FDA Guidance Criteria for Glucose Meter Performance Using Simulation Models.Journal of diabetes science and technology · 2020Article
- Article
- Transcription Errors of Blood Glucose Values and Insulin Errors in an Intensive Care Unit: Secondary Data Analysis Toward Electronic Medical Record-Glucometer Interoperability.JMIR medical informatics · 2019Article
- Assessment of the performance of blood glucose monitoring systems for monitoring dysglycaemia in neonatal patients.BMJ paediatrics open · 2018Article
- Evaluation of point-of-care capillary and venous blood glucose concentrations in hospitalized neonatal foals.Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
11 authors at 4 institutions in 3 countries.
Funding
Abstract
objectivesNew data have emerged from ambulatory and acute care settings about adverse patient events, including death, attributable to erroneous blood glucose meter measurements and leading to questions over their use in critically ill patients. The U.S. Food and Drug Administration published new, more stringent guidelines for glucose meter manufacturers to evaluate the performance of blood glucose meters in critically ill patient settings. The primary objective of this international, multicenter, multidisciplinary clinical study was to develop and apply a rigorous clinical accuracy assessment algorithm, using four distinct statistical tools, to evaluate the clinical accuracy of a blood glucose monitoring system in critically ill patients.
designObservational study.
settingFive international medical and surgical ICUs. PATIENTS: All patients admitted to critical care settings in the centers.
interventionsNone. MEASUREMENTS AND MAIN
resultsGlucose measurements were performed on 1,698 critically ill patients with 257 different clinical conditions and complex treatment regimens. The clinical accuracy assessment algorithm comprised four statistical tools to assess the performance of the study blood glucose monitoring system compared with laboratory reference methods traceable to a definitive standard. Based on POCT12-A3, the Clinical Laboratory Standards Institute standard for hospitals about hospital glucose meter procedures and performance, and Parkes error grid clinical accuracy performance criteria, no clinically significant differences were observed due to patient condition or therapy, with 96.1% and 99.3% glucose results meeting the respective criteria. Stratified sensitivity and specificity analysis (10 mg/dL glucose intervals, 50-150 mg/dL) demonstrated high sensitivity (mean = 95.2%, SD = ± 0.02) and specificity (mean = 95. 8%, SD = ± 0.03). Monte Carlo simulation modeling of the study blood glucose monitoring system showed low probability of category 2 and category 3 insulin dosing error, category 2 = 2.3% (41/1,815) and category 3 = 1.8% (32/1,815), respectively. Patient trend analysis demonstrated 99.1% (223/225) concordance in characterizing hypoglycemic patients.
conclusionsThe multicomponent, clinical accuracy assessment algorithm demonstrated that the blood glucose monitoring system was acceptable for use in critically ill patient settings when compared to the central laboratory reference method. This clinical accuracy assessment algorithm is an effective tool for comprehensively assessing the validity of whole blood glucose measurement in critically ill patient care settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.