ArticleJournal of clinical laboratory analysis2017
Harmonization of serum 25-hydroxycalciferol assay results from high-performance liquid chromatography, enzyme immunoassay, radioimmunoassay, and immunochemiluminescence systems: A multicenter study.
Article in Journal of clinical laboratory analysis, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- The effect of daily intake of vitamin D-fortified yogurt drink, with and without added calcium, on serum adiponectin and sirtuins 1 and 6 in adult subjects with type 2 diabetes.Nutrition & diabetes · 2021Trial
- Response of Vitamin D after Magnesium Intervention in a Postmenopausal Population from the Province of Granada, Spain.Nutrients · 2020Trial
- Development and Evaluation of a Smartphone App-Based Rapid 25-Hydroxy Vitamin D Test.Diagnostics (Basel, Switzerland) · 2025Article
- Vitamin D testing: advantages and limits of the current assays.European journal of clinical nutrition · 2020Review
- Healthy changes in some cardiometabolic risk factors accompany the higher summertime serum 25-hydroxyvitamin D concentrations in Iranian children: National Food and Nutrition Surveillance.Public health nutrition · 2018Article
- Harmonization of serum 25-hydroxycalciferol assay results from high-performance liquid chromatography, enzyme immunoassay, radioimmunoassay, and immunochemiluminescence systems: A multicenter study.Journal of clinical laboratory analysis · 2017Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRemarkable disagreement among different systems of 25-hydroxy vitamin D 25(OH)D assay makes decision making for both clinical and community interventions very difficult. This study aimed to harmonize the results obtained from different 25(OH)D assay systems.
methodsA total of 275 serum samples were analyzed for 25(OH)D using DIAsource-enzyme immunoassay (EIA), DIAsource-radioimmunoassay (RIA), Roche-electrochemiluminescence (ECL), Diasorin-chemiluminescent immunoassay (CLIA), and high-performance liquid chromatography (HPLC), as the reference method. Serum intact parathyroid hormone (iPTH) was also measured in all samples. Between-system agreement and harmonization were evaluated using Bland-Altman analysis, receiver operating characteristic (ROC), and regression analysis.
resultsMean serum 25(OH)D concentrations and frequency distribution of vitamin D status showed a significant difference among the studied systems (P<.001 for both). Serum 25(OH)D assay results from all systems correlated with those from HPLC. As compared with HPLC, ECL showed a positive bias (+3.8 nmol/L), whereas CLIA had a negative bias (-11.9 nmol/L). Both EIA and RIA showed a more or less similar positive bias (8.0 and 8.1 nmol/L, respectively). Using serum iPTH-based 25(OH)D cutoff points, only ECL results became comparable to and without significant difference with HPLC. However, when system-specific cutoffs were defined based on HPLC results using regression equations, mean 25(OH)D and frequency distribution of vitamin D status were more harmonized compared with the other methods.
conclusionOur findings showed that with adjustment of circulating 25(OH)D based on HPLC, frequency distribution of vitamin D status, as judged by different methods, can be well harmonized with no statistically significant inter-system difference.