Evidence map›Paper›PMID 28157430›Full record

ArticleJournal of aerosol medicine and pulmonary drug delivery2017

Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.

Rajoshi Biswas, Nicola A Hanania, Ashutosh Sabharwal

Registry-linked trialAbstract read
In one paragraph

Article in Journal of aerosol medicine and pulmonary drug delivery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02447575 (Detecting Errors In Using Metered Dose Inhalers), which is not on this map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02447575 nacompletednot on this map

Detecting Errors In Using Metered Dose Inhalers (MDI) Among Asthma And Chronic Obstructive Pulmonary Disease (COPD) Patients

TypeinterventionalSponsorBaylor College of MedicineRan2015 to 2019Enrolled23ConditionsAsthma, Chronic Obstructive Pulmonary DiseaseArmsEducation on Use of MDI
3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Rajoshi Biswas1 Department of Electrical and Computer Engineering, Rice University , Houston, Texas.
Nicola A Hanania2 Section of Pulmonary, Critical Care, and Sleep Medicine, Baylor College of Medicine , Houston, Texas.
Ashutosh Sabharwal1 Department of Electrical and Computer Engineering, Rice University , Houston, Texas.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuation at the start of inhalation. However, these recommendations were based on clinical studies using CFC (chlorofluorocarbon)-MDIs and in vitro studies of HFA (hydrofluoroalkane)-MDIs using idealized MDI techniques of uniform inhalation and actuation, disregarding the nonuniform techniques of actual patients.

methodsTo better understand the effects of time-varying MDI usage parameters on lung deposition of aerosol delivered by an HFA-MDI, we conducted an in vitro study modeled on real-life variable inspiratory flow and actuation techniques recorded from 15 subjects with asthma/chronic obstructive pulmonary disease (COPD). We developed a model representing the time-varying inspiratory flow waveforms and actuation timings based on 43 MDI techniques recorded from patients. Furthermore, we constructed an in vitro experimental setup using a mouth-throat cast, programmable MDI actuator, and breath simulator to evaluate lung deposition for the MDI techniques derived from our model.

resultsHigh inspiratory flow rates, 60-90 L/min, consistently resulted in high in vitro lung deposition (>40%) of aerosol (albuterol delivered from Ventolin HFA-MDI) compared to 30 L/min when MDI actuation occurred in the first half of inhalation. Also, positive coordination resulted in higher in vitro lung deposition compared with negative or zero coordination (actuating before or at the start of inspiration). Furthermore, variation in coordination affected lung deposition more significantly (23%) than flow rate or duration of inspiration (≤5%).

conclusionsIn an in vitro experimental model based on inhalation data from patients with asthma and COPD, we demonstrated that aerosol lung deposition emitted from Ventolin HFA-MDI is most optimal for MDI actuation in the first half of inspiration at high flow rates (60-90 L/min).

Indexed as

Drug Delivery SystemsModels, TheoreticalAdministration, InhalationAdolescentAdultAerosolsAgedAged, 80 and overAlbuterolAsthmaBronchodilator AgentsEquipment DesignHumansIn Vitro TechniquesLungMetered Dose InhalersAerosolsAlbuterolBronchodilator AgentsaerosolasthmaCOPDinhaler techniquelung depositionmetered-dose inhaler

Identifiers

PMID28157430
PMCPMC5564031

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.