ArticleBMC musculoskeletal disorders2017
Biomechanical comparison of multilevel lateral interbody fusion with and without supplementary instrumentation: a three-dimensional finite element study.
Article in BMC musculoskeletal disorders, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
35 citing papers in PubMed, 71 citations in OpenAlex.
- Stand-alone prone lateral interbody fusion: a retrospective case series.Journal of spine surgery (Hong Kong) · 2026Article
- The Anterolateral Transpedicular Transverse Process Screw Technique: Surgical Techniques, Biomechanical study and Preliminary Outcomes.Orthopaedic surgery · 2026Article
- Biomechanical Effects of Two Types of 3D-Printed Prosthesis Reconstruction After Single-Segmental Total En Bloc Spondylectomy: A Finite Element Analysis.Orthopaedic surgery · 2026Article
- Verification of ideal screw size, trajectory, and shape for single and double endplate penetrating screw trajectories using osteoporotic vertebral body models based on the finite element method.Asian spine journal · 2026Article
- Biomechanical effects of different bone conditions on oblique lumbar interbody fusion augmented with various fixation options: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026Article
- Impact of Habitual Flexion on Bone Formation After Spinal Fusion Surgery: An In Silico Study.JOR spine · 2025Article
- A Biomechanical Evaluation of a Novel Interspinous Process Device: In Vitro Flexibility Assessment and Finite Element Analysis.Bioengineering (Basel, Switzerland) · 2025Article
- Establishment and validation of a three-dimensional finite element model for degenerative lumbar scoliosis.Frontiers in bioengineering and biotechnology · 2025Article
- Biomechanical changes of oblique lumbar interbody fusion with different fixation techniques in degenerative spondylolisthesis lumbar spine: a finite element analysis.BMC musculoskeletal disorders · 2024Article
- Dislodgment Effects of Different Cage Arrangements in Posterior Lumbar Interbody Fusion: A Finite Element Study.Bioengineering (Basel, Switzerland) · 2024Article
- Comparison of the Fixation Strengths of Screws between the Traditional Trajectory and the Single and Double Endplate Penetrating Screw Trajectories Using Osteoporotic Vertebral Body Models Based on the Finite Element Method.Asian spine journal · 2024Article
- Cortical Endplate Bone Density Measured by Novel Phantomless Quantitative Computed Tomography May Predict Cage Subsidence more Conveniently and Accurately.Orthopaedic surgery · 2023Article
- Biomechanical Comparison of Multilevel Stand-Alone Lumbar Lateral Interbody Fusion With Posterior Pedicle Screws: An In Vitro Study.Neurospine · 2023Article
- Biomechanical Analysis of Double-Level Oblique Lumbar Fusion with Different Types of Fixation: A Finite Element-Based Study.Orthopaedic surgery · 2023Article
- Effect of Interbody Implants on the Biomechanical Behavior of Lateral Lumbar Interbody Fusion: A Finite Element Study.Journal of functional biomaterials · 2023Article
- Construction of the Adjusted Scoliosis 3D Finite Element Model and Biomechanical Analysis under Gravity.Orthopaedic surgery · 2023Article
- Biomechanical study of two-level oblique lumbar interbody fusion with different types of lateral instrumentation: a finite element analysis.Frontiers in medicine · 2023Article
- Recent advancement in finite element analysis of spinal interbody cages: A review.Frontiers in bioengineering and biotechnology · 2023Review
- Instrumentation choice and early radiographic outcome following lateral lumbar interbody fusion (LLIF): Lateral instrumentation versus posterior pedicle screw fixation.North American Spine Society journal · 2022Article
- Effect of the In Situ Screw Implantation Region and Angle on the Stability of Lateral Lumbar Interbody Fusion: A Finite Element Study.Orthopaedic surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundLateral lumbar interbody fusion (LLIF) is a popular, minimally invasive technique that is used to address challenging multilevel degenerative spinal diseases. It remains controversial whether supplemental instrumentation should be added for multilevel LLIF. In this study, we compared the kinematic stability afforded by stand-alone lateral cages with those supplemented by bilateral pedicle screws and rods (PSR), unilateral PSR, or lateral plate (LP) fixation using a finite-element (FE) model of a multi-level LLIF construct with simulated osteoporosis. Additionally, to evaluate the prospect of cage subsidence, the stress change characteristics were surveyed at cage-endplate interfaces.
methodsA nonlinear 3-dimensional FE model of the lumbar spine (L2 to sacrum) was used. After validation, four patterns of instrumented 3-level LLIF (L2-L5) were constructed for this analysis: (a) 3 stand-alone lateral cages (SLC), (b) 3 lateral cages with lateral plate and two screws (parallel to endplate) fixated separately (LPC), (c) 3 lateral cages with bilateral pedicle screw and rod fixation (LC + BPSR), and (d) 3 lateral cages with unilateral pedicle and rod fixation (LC + UPSR). The segmental and overall range of motion (ROM) of each implanted condition were investigated and compared with the intact model. The peak von Mises stresses upon each (superior) endplate and the stress distribution were used for analysis.
resultsBPSR provided the maximum reduction of ROM among the configurations at every plane of motion (66.7-90.9% of intact spine). UPSR also provided significant segmental ROM reduction (45.0-88.3%). SLC provided a minimal restriction of ROM (10.0-75.1%), and LPC was found to be less stable than both posterior fixation (23.9-86.2%) constructs. The construct with stand-alone lateral cages generated greater endplate stresses than did any of the other multilevel LLIF models. For the L3, L4 and L5 endplates, peak endplate stresses caused by the SLC construct exceeded the BPSR group by 52.7, 63.8, and 54.2% in flexion, 22.3, 40.1, and 31.4% in extension, 170.2, 175.1, and 134.0% in lateral bending, and 90.7, 45.5, and 30.0% in axial rotation, respectively. The stresses tended to be more concentrated at the periphery of the endplates.
conclusionsSLC and LPC provided inadequate ROM restriction for the multilevel LLIF constructs, whereas lateral cages with BPSR or UPSR fixation provided favorable biomechanical stability. Moreover, SLC generated significantly higher endplate stress compared with supplemental instrumentation, which may have increased the risk of cage subsidence. Further biomechanical and clinical studies are required to validate our FEA findings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.