Evidence map›Paper›PMID 28150730›Full record

ArticleScientific reports2017

Cell-free measurements of brightness of fluorescently labeled antibodies.

Haiying Zhou, George Tourkakis, Dennis Shi, David M Kim, Hairong Zhang, Tommy Du, William C Eades, Mikhail Y Berezin

Abstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Haiying ZhouDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
George TourkakisDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
Dennis ShiDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
David M KimDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
Hairong ZhangDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
Tommy DuDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.
William C EadesDepartment of Medicine and Siteman Cancer Center Flow Cytometry Core, Washington University School of Medicine, St. Louis, MO 63110, USA.
Mikhail Y BerezinDepartment of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA.

Funding

Washington University Center for Cellular ImagingP30CA091842 · NCI · WASHINGTON UNIVERSITY · PI TIMOTHY J. EBERLEIN · 2001 to 2026
$128.0M
Project 2 - Radiation-Induced Treatment of Multiple Myeloma using NanoparticlesU54CA199092 · NCI · WASHINGTON UNIVERSITY · PI ACHILEFU, SAMUEL · 2015 to 2019
$11.5M
ASSESSMENT OF CHEMOTHERAPY-INDUCED PERIPHERAL NEUROPATHY WITH ACTIVABLE PROBESR21CA198419 · NCI · WASHINGTON UNIVERSITY · PI BEREZIN, MIKHAIL Y. · 2015 to 2016
$365k
FLUORESCENCE SPECTROPHOTOMETER IN NIR RANGE FOR BIOLOGICAL AND MEDICAL APPLICATIOS10RR031621 · NCRR · WASHINGTON UNIVERSITY · PI BEREZIN, MIKHAIL Y. · 2011 to 2011
$292k
NCI NIH HHS P30 CA091842NCI NIH HHS R21 CA198419NCI NIH HHS U54 CA199092NCRR NIH HHS S10 RR031621
6 · The paper itself

Abstract

Validation of imaging contrast agents, such as fluorescently labeled imaging antibodies, has been recognized as a critical challenge in clinical and preclinical studies. As the number of applications for imaging antibodies grows, these materials are increasingly being subjected to careful scrutiny. Antibody fluorescent brightness is one of the key parameters that is of critical importance. Direct measurements of the brightness with common spectroscopy methods are challenging, because the fluorescent properties of the imaging antibodies are highly sensitive to the methods of conjugation, degree of labeling, and contamination with free dyes. Traditional methods rely on cell-based assays that lack reproducibility and accuracy. In this manuscript, we present a novel and general approach for measuring the brightness using antibody-avid polystyrene beads and flow cytometry. As compared to a cell-based method, the described technique is rapid, quantitative, and highly reproducible. The proposed method requires less than ten microgram of sample and is applicable for optimizing synthetic conjugation procedures, testing commercial imaging antibodies, and performing high-throughput validation of conjugation procedures.

Indexed as

Cell-Free SystemFluorescent Antibody TechniqueFluorescent DyesLuminescent MeasurementsStaining and LabelingFlow CytometryHumansImmunoglobulin GMicroscopy, FluorescenceFluorescent DyesImmunoglobulin G

Identifiers

PMID28150730
PMCPMC5288790

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.