ReviewRadiological physics and technology2017
Energy-sensitive photon counting detector-based X-ray computed tomography.
Review in Radiological physics and technology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 85 citations in OpenAlex.
- Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health.Annals of biomedical engineering · 2025Article
- Number of energy windows for photon counting detectors: is more actually more?Journal of medical imaging (Bellingham, Wash.) · 2024Article
- Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study.European radiology · 2024Article
- Approaches, advantages, and challenges to photon counting detector and multi-energy CT.Abdominal radiology (New York) · 2024Review
- Open-Source Data Analysis Tool for Spectral Small-Angle X-ray Scattering Using Spectroscopic Photon-Counting Detector.Sensors (Basel, Switzerland) · 2024Article
- Direct energy binning for photon counting detectors: Simulation study.Medical physics · 2024Article
- Virtual monoenergetic imaging in photon-counting CT of the head and neck.Clinical imaging · 2023Article
- Simultaneous photon counting and charge integrating for pulse pile-up correction in paralyzable photon counting detectors.Physics in medicine and biology · 2023Article
- Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources.Sensors (Basel, Switzerland) · 2023Article
- Model-based pulse pileup and charge sharing compensation for photon counting detectors: A simulation study.Medical physics · 2022Article
- Intelligent Reconstruction Algorithm-Based Computed Tomography Images for Automatic Detection of Gastric Tumor.Computational and mathematical methods in medicine · 2022Article
- Assessment of multi-energy inter-pixel coincidence counters for photon-counting detectors at the presence of charge sharing and pulse pileup: A simulation study.Medical physics · 2021Article
- Computed tomography recent history and future perspectives.Journal of medical imaging (Bellingham, Wash.) · 2021Review
- Photon Counting CT: Clinical Applications and Future Developments.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Assessment of Multienergy Interpixel Coincidence Counters (MEICC) for Charge Sharing Correction or Compensation for Photon Counting Detectors With Boxcar Signals.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients.NPJ breast cancer · 2021Article
- Next-Generation Hardware Advances in CT: Cardiac Applications.Radiology · 2021Review
- Nanoparticle contrast agents for X-ray imaging applications.Wiley interdisciplinary reviews. Nanomedicine and nanobiotechnology · 2020Review
- Spectral photon-counting CT imaging of colorectal peritoneal metastases: initial experience in rats.Scientific reports · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Energy-sensitive photon counting detectors (PCDs) have recently been developed for medical X-ray computed tomography (CT) imaging and a handful of prototype PCD-CT systems have been built and evaluated. PCDs detect X-rays by using mechanisms that are completely different from the current CT detectors (i.e., energy integrating detectors or EIDs); PCDs count photons and obtain the information of the object tissues (i.e., the effective atomic numbers and mass densities) to be imaged. Therefore, these PCDs have the potential not only for evolution-to improve the current CT images such as providing dose reduction-but also for a revolution-to enable novel applications with a new concept such as molecular CT imaging. The performance of PCDs, however, is not flawless, and thus, it requires integrated efforts to develop PCD-CT for clinical use. In this article, we review the current status and the prediction for the future of PCDs, PCD-CT systems, and potential clinical applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.