Evidence map›Paper›PMID 28133595›Full record

ArticleBioresources and bioprocessing2017

Investigation of spiral-wound membrane modules for the cross-flow nanofiltration of fermentation broth obtained from a pilot plant fermentation reactor for the continuous production of lactic acid.

Hendrik Laube, Roland Schneider, Joachim Venus

Open access · diamondAbstract read
In one paragraph

Article in Bioresources and bioprocessing, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 10 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Hendrik LaubeDepartment of Bioengineering, Leibniz-Institute for Agricultural Engineering Potsdam-Bornim e.V., Max-Eyth-Allee 100, 14469 Potsdam, Brandenburg Germany.ORCID 0000-0003-2157-3564
Roland SchneiderDepartment of Bioengineering, Leibniz-Institute for Agricultural Engineering Potsdam-Bornim e.V., Max-Eyth-Allee 100, 14469 Potsdam, Brandenburg Germany.
Joachim VenusDepartment of Bioengineering, Leibniz-Institute for Agricultural Engineering Potsdam-Bornim e.V., Max-Eyth-Allee 100, 14469 Potsdam, Brandenburg Germany.
Leibniz Institute for Agricultural Engineering and Bioeconomy · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe separation performance of seven polymer membranes for the nanofiltration of sodium lactate in fermentation broth was investigated. Each module was introduced into the test stand, and the system curve was obtained by recording the permeate flow velocity at different pump head levels. Performance benchmarks were good permeate quality, as determined by high permeate flow velocity, high sodium lactic concentration, low ion impurity concentration, and low organic impurity concentration. Market research has shown that three companies, DOW (TW30, SW30, NF45), General Electric (DK73, DL73), and Microdyn-Nadir (NP30), distributed spiral-wound membrane modules for cross-flow filtration in a 2.5 by 40-in. module size, suitable for operation in the filtration test stand.

resultsThe measured permeate flow velocity was found to vary widely between the membranes. At a pump head of 250 m, DK73, NP30, and DL73 generated more than 200, 300, and 400% higher permeate flow velocities, respectively, than TW30 and NF45. A key benchmark, lactate rejection, was also highly dependent upon membrane type. The NP30, NF45, and TW30 membranes showed a decrease in lactate permeate flow velocity of 117, 83, and 348% starting at 205, 250, and 300 m, respectively.

conclusionsThe DL73 had the overall best performance according to the measured fermentation broth and lactic acid permeability. The presented method for the graphical analysis of the membrane performance proofed to be a useful tool for the filtration engineer.

Indexed as

Cross-flowNanofiltrationPilot plantSodium lactateSpiral-wound modules

Identifiers

PMID28133595
PMCPMC5236076
OpenAlexW2578742603

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.