Evidence map›Paper›PMID 28124761›Full record

ArticleBiomedical microdevices2017

Laboratory and clinical reliability of conformally coated subretinal implants.

Renate Daschner, Udo Greppmaier, Martin Kokelmann, Sandra Rudorf, Ralf Rudorf, Sebastian Schleehauf, Walter G Wrobel

Open access · hybridAbstract read
In one paragraph

Article in Biomedical microdevices, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 43 citations in OpenAlex.

  1. Trial
  2. Review
  3. Electronic Retinal Prostheses.Cold Spring Harbor perspectives in medicine · 2023
    Review
  4. Article
  5. Article
  6. Article
  7. Optoelectronic Devices for Vision Restoration.Current ophthalmology reports · 2020
    Article
  8. An update on retinal prostheses.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2020
    Review
  9. Article
  10. Article
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Renate DaschnerRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany. renate.daschner@retina-implant.de.ORCID 0000-0001-5307-2276
Udo GreppmaierRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
Martin KokelmannRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
Sandra RudorfRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
Ralf RudorfRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
Sebastian SchleehaufRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
Walter G WrobelRetina Implant AG, Gerhard-Kindler-Strasse 8, 72770, Reutlingen, Germany.
K-Implant (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Despite recent developments and new treatments in ophthalmology there is nothing available to cure retinal degenerations like Retinitis Pigmentosa (RP) yet. One of the most advanced approaches to treat people that have gone blind due to RP is to replace the function of the degenerated photoreceptors by a microelectronic neuroprosthetic device. Basically, this subretinal active implant transforms the incoming light into electric pulses to stimulate the remaining cells of the retina. The functional time of such devices is a crucial aspect. In this paper the laboratory and clinical reliability of the two active subretinal implants Alpha IMS and Alpha AMS is presented. Based on clinical data the median operating life of the Alpha AMS is estimated to be 3.3 years with a one-sided lower 75 % confidence level of 2.0 years. This data shows a significant improvement of the device lifetime compared to the previous device Alpha IMS which shows a median lifetime of 0.6 years with a lower confidence bound (75 %) of 0.5 years. The results are in good agreement with laboratory data from accelerated aging tests of the implant components, showing an estimated median lifetime for Alpha IMS components of 0.7 years compared to the improved lifetime of Alpha AMS of 4.7 years.

Indexed as

LaboratoriesRetinaVisual ProsthesisClinical Trials as TopicHumansKaplan-Meier EstimateProsthesis DesignReproducibility of ResultsArtificial visionClinical reliabilityElectronic implantsNeuroprostheticsRetinitis pigmentosa

Identifiers

PMID28124761
PMCPMC5269461
OpenAlexW2580242474

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked