A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.

N Boubouchairopoulou, A Kollias, B Chiu, B Chen, S Lagou, P Anestis, G S Stergiou

Abstract readClinical TrialValidation Study
PubMed Publisher
In one paragraph

Trial report in Journal of human hypertension, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 44 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Assessment of a Calibration-Free Method of Cuffless Blood Pressure Measurement: A Pilot Study.IEEE journal of translational engineering in health and medicine · 2023
    Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Cuffless Blood Pressure Devices.American journal of hypertension · 2022
    Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Cuff-Less Methods for Blood Pressure Telemonitoring.Frontiers in cardiovascular medicine · 2019
    Review
  17. Article
  18. Article
  19. Improvement of Diurnal Blood Pressure Variation by Azilsartan.Journal of clinical medicine research · 2018
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

N BoubouchairopoulouHypertension Center STRIDE-7, Third Department of Medicine, National and Kapodistrian University of Athens, School of Medicine, Sotiria Hospital, Athens, Greece.
A KolliasHypertension Center STRIDE-7, Third Department of Medicine, National and Kapodistrian University of Athens, School of Medicine, Sotiria Hospital, Athens, Greece.
B ChiuMaisense Inc., Zhubei, Taiwan.
B ChenMaisense Inc., Zhubei, Taiwan.
S LagouHypertension Center STRIDE-7, Third Department of Medicine, National and Kapodistrian University of Athens, School of Medicine, Sotiria Hospital, Athens, Greece.
P AnestisHypertension Center STRIDE-7, Third Department of Medicine, National and Kapodistrian University of Athens, School of Medicine, Sotiria Hospital, Athens, Greece.
G S StergiouHypertension Center STRIDE-7, Third Department of Medicine, National and Kapodistrian University of Athens, School of Medicine, Sotiria Hospital, Athens, Greece.
Sotiria General Hospital · GRNational and Kapodistrian University of Athens · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A pocket-size cuffless electronic device for self-measurement of blood pressure (BP) has been developed (Freescan, Maisense Inc., Zhubei, Taiwan). The device estimates BP within 10 s using three embedded electrodes and one force sensor that is applied over the radial pulse to evaluate the pulse wave. Before use, basic anthropometric characteristics are recorded on the device, and individualized initial calibration is required based on a standard BP measurement performed using an upper-arm BP monitor. The device performance in providing valid BP readings was evaluated in 313 normotensive and hypertensive adults in three study phases during which the device sensor was upgraded. A formal validation study of a prototype device against mercury sphygmomanometer was performed according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 2013 protocol. The test device succeeded in obtaining a valid BP measurement (three successful readings within up to five attempts) in 55-72% of the participants, which reached 87% with device sensor upgrade. For the validation study, 125 adults were recruited and 85 met the protocol requirements for inclusion. The mean device-observers BP difference was 3.2±6.7 (s.d.) mm Hg for systolic and 2.6±4.6 mm Hg for diastolic BP (criterion 1). The estimated s.d. (inter-subject variability) were 5.83 and 4.17 mm Hg respectively (criterion 2). These data suggest that this prototype cuffless BP monitor provides valid self-measurements in the vast majority of adults, and satisfies the BP measurement accuracy criteria of the ANSI/AAMI/ISO 2013 validation protocol.

Indexed as

AdultAgedBlood Pressure DeterminationFeasibility StudiesFemaleHumansMaleMiddle AgedSelf Care

Identifiers

PMID28124684
OpenAlexW2581088985

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.