A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.
Trial report in Journal of human hypertension, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 44 citations in OpenAlex.
- Wearable, cuffless, and portable devices for blood pressure monitoring (2015-2025): a scoping review of technologies, calibration, clinical validation, and regulatory frameworks.Frontiers in digital health · 2026Article
- Clinical validation of a wearable ultrasound sensor of blood pressure.Nature biomedical engineering · 2025Article
- Cuffless Blood Pressure Monitor for Home and Hospital Use.Sensors (Basel, Switzerland) · 2025Review
- Automatic Calibration of a Device for Blood Pressure Waveform Measurement.Sensors (Basel, Switzerland) · 2023Article
- Assessment of a Calibration-Free Method of Cuffless Blood Pressure Measurement: A Pilot Study.IEEE journal of translational engineering in health and medicine · 2023Article
- Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges.Bioengineering (Basel, Switzerland) · 2022Review
- Challenges Presented by Cuffless Measurement of Blood Pressure if Adopted for Diagnosis and Treatment of Hypertension.Pulse (Basel, Switzerland) · 2022Article
- An Arterial Compliance Sensor for Cuffless Blood Pressure Estimation Based on Piezoelectric and Optical Signals.Micromachines · 2022Article
- Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis.European heart journal. Digital health · 2022Review
- Cuffless Blood Pressure Devices.American journal of hypertension · 2022Review
- Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals.Hypertension (Dallas, Tex. : 1979) · 2021Review
- Point-of-care testing technologies for the home in chronic kidney disease: a narrative review.Clinical kidney journal · 2021Article
- The first study comparing a wearable watch-type blood pressure monitor with a conventional ambulatory blood pressure monitor on in-office and out-of-office settings.Journal of clinical hypertension (Greenwich, Conn.) · 2020Article
- Diagnostic accuracy of a novel cuffless self-blood pressure monitor for atrial fibrillation screening in the elderly.Journal of clinical hypertension (Greenwich, Conn.) · 2019Article
- Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study.Journal of medical Internet research · 2019Article
- Cuff-Less Methods for Blood Pressure Telemonitoring.Frontiers in cardiovascular medicine · 2019Review
- Blood Pressure Measurement Validation Off the Cuff? Comment on "A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study".Journal of medical Internet research · 2018Article
- A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices.Journal of medical Internet research · 2018Article
- Improvement of Diurnal Blood Pressure Variation by Azilsartan.Journal of clinical medicine research · 2018Article
- Development and Validation of a Novel Cuff-Less Blood Pressure Monitoring Device.JACC. Basic to translational science · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A pocket-size cuffless electronic device for self-measurement of blood pressure (BP) has been developed (Freescan, Maisense Inc., Zhubei, Taiwan). The device estimates BP within 10 s using three embedded electrodes and one force sensor that is applied over the radial pulse to evaluate the pulse wave. Before use, basic anthropometric characteristics are recorded on the device, and individualized initial calibration is required based on a standard BP measurement performed using an upper-arm BP monitor. The device performance in providing valid BP readings was evaluated in 313 normotensive and hypertensive adults in three study phases during which the device sensor was upgraded. A formal validation study of a prototype device against mercury sphygmomanometer was performed according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 2013 protocol. The test device succeeded in obtaining a valid BP measurement (three successful readings within up to five attempts) in 55-72% of the participants, which reached 87% with device sensor upgrade. For the validation study, 125 adults were recruited and 85 met the protocol requirements for inclusion. The mean device-observers BP difference was 3.2±6.7 (s.d.) mm Hg for systolic and 2.6±4.6 mm Hg for diastolic BP (criterion 1). The estimated s.d. (inter-subject variability) were 5.83 and 4.17 mm Hg respectively (criterion 2). These data suggest that this prototype cuffless BP monitor provides valid self-measurements in the vast majority of adults, and satisfies the BP measurement accuracy criteria of the ANSI/AAMI/ISO 2013 validation protocol.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.