SynthesisThe Cochrane database of systematic reviews2017
Imaging for the exclusion of pulmonary embolism in pregnancy.
Synthesis in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed, 4 syntheses or guidelines pooled it, 77 citations in OpenAlex.
- D-dimer to rule out venous thromboembolism during pregnancy: A systematic review and meta-analysis.Journal of thrombosis and haemostasis : JTH · 2021Pooled it
- Computed tomography pulmonary angiographyHaematologica · 2019Pooled it
- American Society of Hematology 2018 guidelines for management of venous thromboembolism: venous thromboembolism in the context of pregnancy.Blood advances · 2018Guideline
- Imaging for the exclusion of pulmonary embolism in pregnancy.The Cochrane database of systematic reviews · 2017Pooled it
- Quantitative evaluation of 3D-printed physiological visualization tools in enhancing interns' knowledge retention and application.Frontiers in medicine · 2026Article
- Postoperative venous thromboembolism following cesarean delivery: prevalence, pathophysiology, diagnosis, treatment, and prevention.American journal of obstetrics and gynecology · 2026Review
- Diagnosing Pulmonary Embolism During Pregnancy.Chest · 2025Review
- Pregnancy-Related Cardiovascular Diseases: A Radiological Overview.Journal of cardiovascular development and disease · 2025Review
- Pulmonary Embolism in Pregnancy: A Review for Clinical Practitioners.Journal of clinical medicine · 2024Review
- The radiological diagnosis of pregnancy associated venous thromboembolism: a review of current research.Frontiers in medicine · 2024Review
- Prevention, diagnosis, and management of PE and DVT in pregnant women.Hematology. American Society of Hematology. Education Program · 2023Review
- [Assessment of pulmonary embolism related to active SARS-CoV-2 infection in pregnant women.]Revista espanola de medicina nuclear e imagen molecular · 2022Article
- Risk of neonatal hypothyroidism in newborns from mothers exposed to CTPA during pregnancy: Ancillary data from a prospective outcome study.Journal of thrombosis and haemostasis : JTH · 2022Article
- Making decisions about radiological imaging in pregnancy.BMJ (Clinical research ed.) · 2022Article
- Imaging modalities for confirming pulmonary embolism during pregnancy: results from a multicenter international study.European radiology · 2022Article
- Pulmonary Embolism and Pregnancy-Challenges in Diagnostic and Therapeutic Decisions in High-Risk Patients.Frontiers in cardiovascular medicine · 2022Review
- Breast dose matters.Haematologica · 2021Article
- Phenotyping placental oxygenation in Lgals1 deficient mice usingScientific reports · 2021Article
- Diagnostic imaging to investigate pulmonary embolism in pregnancy using CT-Pulmonary angiography versus perfusion scan.Journal of research in medical sciences : the official journal of Isfahan University of Medical Sciences · 2021Article
- Can pregnancy-adapted algorithms avoid diagnostic imaging for pulmonary embolism?Hematology. American Society of Hematology. Education Program · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundPulmonary embolism is a leading cause of pregnancy-related death. An accurate diagnosis in pregnant patients is crucial to prevent untreated pulmonary embolism as well as unnecessary anticoagulant treatment and future preventive measures. Applied imaging techniques might perform differently in these younger patients with less comorbidity and altered physiology, who largely have been excluded from diagnostic studies.
objectivesTo determine the diagnostic accuracy of computed tomography pulmonary angiography (CTPA), lung scintigraphy and magnetic resonance angiography (MRA) for the diagnosis of pulmonary embolism during pregnancy. SEARCH
methodsWe searched MEDLINE and Embase until July 2015. We used included studies as seeds in citations searches and in 'find similar' functions and searched reference lists. We approached experts in the field to help us identify non-indexed studies. SELECTION CRITERIA: We included consecutive series of pregnant patients suspected of pulmonary embolism who had undergone one of the index tests (computed tomography (CT) pulmonary angiography, lung scintigraphy or MRA) and clinical follow-up or pulmonary angiography as a reference test. DATA COLLECTION AND ANALYSIS: Two review authors performed data extraction and quality assessment. We contacted investigators of potentially eligible studies to obtain missing information. In the primary analysis, we regarded inconclusive index test results as a negative reference test, and treatment for pulmonary embolism after an inconclusive index test as a positive reference test. MAIN
resultsWe included 11 studies (four CTPA, five lung scintigraphy, two both) with a total of 695 CTPA and 665 lung scintigraphy results. Lung scintigraphy was applied by different techniques. No MRA studies matched our inclusion criteria.Overall, risk of bias and concerns regarding applicability were high in all studies as judged in light of the review research question, as was heterogeneity in study methods. We did not undertake meta-analysis. All studies used clinical follow-up as a reference standard, none in a manner that enabled reliable identification of false positives. Sensitivity and negative predictive value were therefore the only valid test accuracy measures.The median negative predictive value for CTPA was 100% (range 96% to 100%). Median sensitivity was 83% (range 0% to 100%).The median negative predictive value for lung scintigraphy was 100% (range 99% to 100%). Median sensitivity was 100% (range 0% to 100%).The median frequency of inconclusive results was 5.9% (range 0.9% to 36%) for CTPA and 4.0% (range 0% to 23%) for lung scintigraphy. The overall median prevalence of pulmonary embolism was 3.3% (range 0.0% to 8.7%). AUTHORS'
conclusionsBoth CTPA and lung scintigraphy seem appropriate for exclusion of pulmonary embolism during pregnancy. However, the quality of the evidence mandates cautious adoption of this conclusion. Important limitations included poor reference standards, necessary assumptions in the analysis regarding inconclusive test results and the inherent inability of included studies to identify false positives. It is unclear which test has the highest accuracy. There is a need for direct comparisons between diagnostic methods, including MR, in prospective randomized diagnostic studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.