Evidence map›Paper›PMID 28124104›Full record

ArticleInternational orthopaedics2017

The linear penetration rate is not relevant for evaluating wear of dual mobility cups: an explant study.

Bertrand Boyer, Thomas Neri, Alexandre Di Iorio, Jean Geringer, Remi Philippot, Frederic Farizon

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
3.5field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Dual-mobility cup: a new French revolution.International orthopaedics · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Bertrand BoyerMines de Saint-Etienne, Unité SAINBIOSE, INSERM U1059, Université de Lyon-St Etienne, St Etienne, France. bertrand.boyer@chu-st-etienne.fr.ORCID 0000-0001-6427-9491
Thomas NeriLaboratoire de Physiologie de l'Exercice, Centre d'Orthopédie Traumatologie CHU St Etienne, Université Jean Monnet, St Etienne, 42055, Cedex 2, France.
Alexandre Di IorioLaboratoire de Physiologie de l'Exercice, Centre d'Orthopédie Traumatologie CHU St Etienne, Université Jean Monnet, St Etienne, 42055, Cedex 2, France.
Jean GeringerMines de Saint-Etienne, Unité SAINBIOSE, INSERM U1059, Université de Lyon-St Etienne, St Etienne, France.
Remi PhilippotLaboratoire de Physiologie de l'Exercice, Centre d'Orthopédie Traumatologie CHU St Etienne, Université Jean Monnet, St Etienne, 42055, Cedex 2, France.
Frederic FarizonLaboratoire de Physiologie de l'Exercice, Centre d'Orthopédie Traumatologie CHU St Etienne, Université Jean Monnet, St Etienne, 42055, Cedex 2, France.
Université Jean Monnet · FRUniversité Claude Bernard Lyon 1 · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe linear penetration rate (LPR) has been used to estimate volumetric wear ever since metal-on-polyethylene bearings were first introduced. Annual volumetric wear and osteolysis are interrelated. The use of dual mobility cups has increased; however, the presence of two bearings needs paraclinical monitoring of wear to anticipate potential wear-related complications. Is LPR correlated to volumetric wear?

methodsNinety-eight dual mobility liner retrievals were mapped in three-dimensions (3D) with a fully automatic stripe light scanner. Martell's method was applied to 3D maps of the explants to determine how much the centres of the inner and outer bearings had shifted in the three planes, and in particular, penetration of the femoral head in the "z" axis. The total, inner and outer wear volumes were then compared to the shift in the centres of rotation (COR) and the pre-operative X-rays.

resultsThere was no relationship between wear and head penetration into the liner. There was a statistically significant relationship between the 3D centre of rotation shift and inner wear or total wear. Wear was multidirectional.

conclusionsLPR is ineffective for estimating wear of dual mobility inserts, since its wear not two-dimensional. In the future, a 3D imaging method with very thin slices could be used to monitor the wear of dual mobility inserts by measuring the shift in the centres of rotation, once artifacts are overcome.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisHumansImaging, Three-DimensionalProsthesis DesignProsthesis FailureRetrospective StudiesTime FactorsDual mobilityExplant analysisLinear penetration rateTotal hip replacementWear

Identifiers

PMID28124104
OpenAlexW2581036922

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.