Evidence map›Paper›PMID 28121993›Full record

ArticlePloS one2017

A Comparison of Three Quantitative Methods to Estimate G6PD Activity in the Chittagong Hill Tracts, Bangladesh.

Benedikt Ley, Mohammad Shafiul Alam, James J O'Donnell, Mohammad Sharif Hossain, Mohammad Golam Kibria, Nusrat Jahan, Wasif A Khan, Kamala Thriemer, Mark D Chatfield, Ric N Price and 1 more

Open access · goldAbstract readComparative StudyValidation Study
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed, 2 pooled it
12.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed, 2 syntheses or guidelines pooled it, 68 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Application of genetic screening processor in screening neonatal glucose-6-phosphate dehydrogenase deficiency.Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences · 2021
    Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 3 countries.

Benedikt LeyGlobal and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia.
Mohammad Shafiul AlamInfectious Diseases Division, International Centre for Diarrheal Diseases Research, Bangladesh, Mohakhali, Dhaka, Bangladesh.
James J O'DonnellCentre for Biomedical Research, Burnet Institute, Melbourne, Victoria, Australia.
Mohammad Sharif HossainCentre for Biomedical Research, Burnet Institute, Melbourne, Victoria, Australia.
Mohammad Golam KibriaInfectious Diseases Division, International Centre for Diarrheal Diseases Research, Bangladesh, Mohakhali, Dhaka, Bangladesh.
Nusrat JahanInfectious Diseases Division, International Centre for Diarrheal Diseases Research, Bangladesh, Mohakhali, Dhaka, Bangladesh.
Wasif A KhanInfectious Diseases Division, International Centre for Diarrheal Diseases Research, Bangladesh, Mohakhali, Dhaka, Bangladesh.
Kamala ThriemerGlobal and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia.
Mark D ChatfieldGlobal and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia.
Ric N PriceGlobal and Tropical Health Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia.
Jack S RichardsCentre for Biomedical Research, Burnet Institute, Melbourne, Victoria, Australia.
International Centre for Diarrhoeal Disease Research · BDCharles Darwin University · AUBurnet Institute · AUMenzies School of Health Research · AUPeter Doherty Institute · AU

Funding

Wellcome Trust 200909/Z/16/Z
6 · The paper itself

Abstract

backgroundGlucose-6-phosphate-dehydrogenase-deficiency (G6PDd) is a major risk factor for primaquine-induced haemolysis. There is a need for improved point-of-care and laboratory-based G6PD diagnostics to unsure safe use of primaquine.

methodsG6PD activities of participants in a cross-sectional survey in Bangladesh were assessed using two novel quantitative assays, the modified WST-8 test and the CareStart™ G6PD Biosensor (Access Bio), The results were compared with a gold standard UV spectrophotometry assay (Randox). The handheld CareStart™ Hb instrument (Access Bio) is designed to be a companion instrument to the CareStart™ G6PD biosensor, and its performance was compared to the well-validated HemoCue™ method. All quantitative G6PD results were normalized with the HemoCue™ result.

resultsA total of 1002 individuals were enrolled. The adjusted male median (AMM) derived by spectrophotometry was 7.03 U/g Hb (interquartile range (IQR): 5.38-8.69), by WST-8 was 7.03 U/g Hb (IQR: 5.22-8.16) and by Biosensor was 8.61 U/g Hb (IQR: 6.71-10.08). The AMM between spectrophotometry and WST-8 did not differ (p = 1.0) but differed significantly between spectrophotometry and Biosensor (p<0.01). Both, WST-8 and Biosensor were correlated with spectrophotometry (rs = 0.5 and rs = 0.4, both p<0.001). The mean difference in G6PD activity was -0.12 U/g Hb (95% limit of agreement (95% LoA): -5.45 to 5.20) between spectrophotometry and WST-8 and -1.74U/g Hb (95% LoA: -7.63 to 4.23) between spectrophotometry and Biosensor. The WST-8 identified 55.1% (49/89) and the Biosensor 19.1% (17/89) of individuals with G6PD activity <30% by spectrophotometry. Areas under the ROC curve did not differ significantly for the WST-8 and Biosensor irrespective of the cut-off activity applied (all p>0.05). Sensitivity and specificity for detecting G6PD activity <30% was 0.55 (95% confidence interval (95%CI): 0.44-0.66) and 0.98 (95%CI: 0.97-0.99) respectively for the WST-8 and 0.19 (95%CI: 0.12-0.29) and 0.99 (95%CI: 0.98-0.99) respectively for the Biosensor. Hb concentrations measured by HemoCue™ and CareStart™ Hb were strongly correlated (rs = 0.8, p<0.001, mean difference = 0.09 g Hb/dL, 95% LoA: -2.15 to 2.34).

conclusionWST-8 and the CareStart™ G6PD Biosensor represent advances in G6PD diagnostics in resource poor settings, but will require further development before clinical deployment. The CareStart™ Hb instrument produced a precise measure of haemoglobin concentration.

Indexed as

Biosensing TechniquesColorimetrySpectrophotometry, UltravioletAdolescentAdultAgedAged, 80 and overBangladeshChildChild, PreschoolCross-Sectional StudiesEndemic DiseasesFemaleGlucosephosphate DehydrogenaseGlucosephosphate Dehydrogenase DeficiencyHemoglobinsGlucosephosphate DehydrogenaseHemoglobins

Identifiers

PMID28121993
PMCPMC5266301
OpenAlexW2582844219

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked