Trial reportJAMA2017
Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.
Trial report in JAMA, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 11 registered trials, which are not on this map. Cited by 584 papers, 9 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Multiple Daily Injections and Continuous Glucose Monitoring in Diabetes
Continuous Glucose Monitoring in the Hospital to Aid in Care and Improve Transition of Care to Outpatient
Assessment of the Accuracy of Continuous Glucose Sensors in People With Diabetes Undergoing Haemodialysis
Comparison of CGM in Randomised Study of Real-time and Intermittently-scanned Systems in T1D With Normal Awareness of Hypoglycemia (CORRIDA)
Transition of Patients With T1D From Multiple Daily Injection (MDI) and Self-Monitoring of Blood Glucose (SMBG) Directly to MiniMed™ 780G Advanced Hybrid Closed Loop (AHCL) System :Impact on Glucose Control and Quality of Life Measures
Comparison of CGM in Non-randomised Real Life Study of Real-time and Intermittently Scanned Systems in Patients With Type 1 Diabetes
Continuous Glucose Monitoring (CGM) to Improve Glycemic Control in Kidney Transplant Recipients
Three-arm Pragmatic Randomized Study on the Effectiveness, Feasibility, Acceptability, and Cost of the Use of Continuous Glucose Monitoring Devices Among People Living With Type 1 Diabetes in South Africa
Use of Continuous Glucose Monitoring Devices Among People Living With Type 1 Diabetes in Kenya: A Three-arm Pragmatic Randomized Study on the Effectiveness, Feasibility, Acceptability, and Cost.
Supporting Primary Care Adoption, Resources, and Knowledge for Continuous Glucose Monitoring
Implementation of Networked Continuous Glucose Monitoring With Telemetry Within the Intensive Care Unit (ICU-TeleCGM)
Who cites it
584 citing papers in PubMed, 9 syntheses or guidelines pooled it, 1,122 citations in OpenAlex.
- Efficacy of continuous glucose monitoring in comparison to self-blood glucose monitoring in patients with type 2 diabetes mellitus under insulin treatment: a systematic review and meta-analysis.BMC endocrine disorders · 2026Pooled it
- The therapeutic efficacy of continuous glucose monitoring in diabetes: an updated meta-analysis with meta-regression.Endocrine · 2025Pooled it
- Perioperative use and accuracy of continuous glucose monitoring: A systematic review.Diabetes, obesity & metabolism · 2025Pooled it
- Using technology to support diabetes care in hospital: Guidelines from the Joint British Diabetes Societies for Inpatient Care (JBDS-IP) group and Diabetes Technology Network (DTN) UK.Diabetic medicine : a journal of the British Diabetic Association · 2025Guideline
- Hybrid closed-loop systems for managing blood glucose levels in type 1 diabetes: a systematic review and economic modelling.Health technology assessment (Winchester, England) · 2024Pooled it
- Evaluating the Cost-Utility of Continuous Glucose Monitoring in Individuals with Type 1 Diabetes: A Systematic Review of the Methods and Quality of Studies Using Decision Models or Empirical Data.PharmacoEconomics · 2024Pooled it
- 2023 Clinical Practice Guidelines for Diabetes Management in Korea: Full Version Recommendation of the Korean Diabetes Association.Diabetes & metabolism journal · 2024Guideline
- International Society for Pediatric and Adolescent Diabetes Clinical Practice Consensus Guidelines 2024 Diabetes Technologies: Glucose Monitoring.Hormone research in paediatrics · 2024Guideline
- Patient experiences of continuous glucose monitoring and sensor-augmented insulin pump therapy for diabetes: A systematic review of qualitative studies.Journal of diabetes · 2023Pooled it
- Real-Time Continuous Glucose Monitoring Among People With Type 2 Diabetes and End-Stage Kidney Failure Undergoing Maintenance Hemodialysis: A Randomized Clinical Trial.Diabetes care · 2026Trial
- Rapid improvements in glycemic management with use of continuous glucose monitoring in adults with type 2 diabetes treated with basal insulin: 3-month analysis of the MOBILE study.BMJ open diabetes research & care · 2025Trial
- A Bayesian decision support system for automated insulin doses in adults with type 1 diabetes on multiple daily injections: a randomized controlled trial.Nature communications · 2025Trial
- Trial
- Use of Freestyle Libre 2.0 in children with type 1 diabetes mellitus and elevated HbADiabetic medicine : a journal of the British Diabetic Association · 2025Trial
- Trial
- Impact of a point-of-care urine tenofovir assay on adherence to HIV pre-exposure prophylaxis among women in Kenya: a randomised pilot trial.The lancet. HIV · 2024Trial
- Trial
- The Impact of Baseline User Characteristics on the Benefits of Real-Time Versus Intermittently Scanned Continuous Glucose Monitoring in Adults With Type 1 Diabetes: Moderator Analyses of the ALERTT1 Trial.Journal of diabetes science and technology · 2024Trial
- Continuous Glucose Monitoring Metrics and Risks of Severe Hypoglycemia and Diabetic Ketoacidosis in Type 1 Diabetes: A Pooled Analysis.Diabetes care · 2026Article
- Weight and HbA1c trajectories following initiation of continuous glucose monitoring in adults with type 1 diabetes: a cohort study using group-based multi-trajectory analysis.The Lancet regional health. Europe · 2026Article
524 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
14 authors at 6 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Previous clinical trials showing the benefit of continuous glucose monitoring (CGM) in the management of type 1 diabetes predominantly have included adults using insulin pumps, even though the majority of adults with type 1 diabetes administer insulin by injection. Objective: To determine the effectiveness of CGM in adults with type 1 diabetes treated with insulin injections. Design, Setting, and Participants: Randomized clinical trial conducted between October 2014 and May 2016 at 24 endocrinology practices in the United States that included 158 adults with type 1 diabetes who were using multiple daily insulin injections and had hemoglobin A1c (HbA1c) levels of 7.5% to 9.9%. Interventions: Random assignment 2:1 to CGM (n = 105) or usual care (control group; n = 53). Main Outcomes and Measures: Primary outcome measure was the difference in change in central-laboratory-measured HbA1c level from baseline to 24 weeks. There were 18 secondary or exploratory end points, of which 15 are reported in this article, including duration of hypoglycemia at less than 70 mg/dL, measured with CGM for 7 days at 12 and 24 weeks. Results: Among the 158 randomized participants (mean age, 48 years [SD, 13]; 44% women; mean baseline HbA1c level, 8.6% [SD, 0.6%]; and median diabetes duration, 19 years [interquartile range, 10-31 years]), 155 (98%) completed the study. In the CGM group, 93% used CGM 6 d/wk or more in month 6. Mean HbA1c reduction from baseline was 1.1% at 12 weeks and 1.0% at 24 weeks in the CGM group and 0.5% and 0.4%, respectively, in the control group (repeated-measures model P < .001). At 24 weeks, the adjusted treatment-group difference in mean change in HbA1c level from baseline was -0.6% (95% CI, -0.8% to -0.3%; P < .001). Median duration of hypoglycemia at less than <70 mg/dL was 43 min/d (IQR, 27-69) in the CGM group vs 80 min/d (IQR, 36-111) in the control group (P = .002). Severe hypoglycemia events occurred in 2 participants in each group. Conclusions and Relevance: Among adults with type 1 diabetes who used multiple daily insulin injections, the use of CGM compared with usual care resulted in a greater decrease in HbA1c level during 24 weeks. Further research is needed to assess longer-term effectiveness, as well as clinical outcomes and adverse effects. Trial Registration: clinicaltrials.gov Identifier: NCT02282397.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.