ArticleThe western journal of emergency medicine2017
Adapting Gel Wax into an Ultrasound-Guided Pericardiocentesis Model at Low Cost.
Article in The western journal of emergency medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 36 citations in OpenAlex.
- Low-cost simulation models for soft-tissue procedures for medical student education in Rwanda.BMC medical education · 2025Article
- Article
- Pericardiocentesis simulation model: conception and development.Acta cirurgica brasileira · 2025Article
- How to enhance the novices' learning in ultrasound-guided procedures utilizing handmade phantoms?BMC medical education · 2024Observational
- A feasibility study of a handmade ultrasound-guided phantom for paracentesis.BMC medical education · 2024Article
- An infant phantom for pediatric pericardial access and electrophysiology training.Heart rhythm O2 · 2022Article
- A Novel, Low-cost, Low-fidelity Pericardiocentesis Teaching Model.The western journal of emergency medicine · 2021Article
- Review of simulation model for education of point-of-care ultrasound using easy-to-make tools.World journal of clinical cases · 2020Review
- Novel paediatric pericardiocentesis simulator: a collaboration between the Departments of Pediatrics and Biomedical Engineering.BMJ simulation & technology enhanced learning · 2020Article
- Modification of Daly's Do-it-yourself, Ultrasound-guided Pericardiocentesis Model for Added External Realism.The western journal of emergency medicine · 2018Article
- Acute Cardiac Tamponade: An Adult Simulation Case for Residents.MedEdPORTAL : the journal of teaching and learning resources · 2016Article
- Homemade cardiac and vein cannulation ultrasound phantoms for trauma management training in resource-limited settings.Avicenna journal of medicineArticle
Corrections and comments
- Commented on by
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cardiac tamponade is a life-threatening emergency for which pericardiocentesis may be required. Real-time bedside ultrasound has obviated the need for routine blind procedures in cardiac arrest, and the number of pericardiocenteses being performed has declined. Despite this fact, pericardiocentesis remains an essential skill in emergency medicine. While commercially available training models exist, cost, durability, and lack of anatomical landmarks limit their usefulness. We sought to create a pericardiocentesis model that is realistic, simple to build, reusable, and cost efficient. We constructed the model using a red dye-filled ping pong ball (simulating the right ventricle) and a 250cc normal saline bag (simulating the effusion) encased in an artificial rib cage and held in place by gel wax. The inner saline bag was connected to a 1L saline bag outside of the main assembly to act as a fluid reservoir for repeat uses. The entire construction process takes approximately 16-20 hours, most of which is attributed to cooling of the gel wax. Actual construction time is approximately four hours at a cost of less than $200. The model was introduced to emergency medicine residents and medical students during a procedure simulation lab and compared to a model previously described by dell'Orto.1 The learners performed ultrasound-guided pericardiocentesis using both models. Learners who completed a survey comparing realism of the two models felt our model was more realistic than the previously described model. On a scale of 1-9, with 9 being very realistic, the previous model was rated a 4.5. Our model was rated a 7.8. There was also a marked improvement in the perceived recognition of the pericardium, the heart, and the pericardial sac. Additionally, 100% of the students were successful at performing the procedure using our model. In simulation, our model provided both palpable and ultrasound landmarks and held up to several months of repeated use. It was less expensive than commercial models ($200 vs up to $16,500) while being more realistic in simulation than other described "do-it-yourself models." This model can be easily replicated to teach the necessary skill of pericardiocentesis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.