Trial reportInvestigative ophthalmology & visual science2017
Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography.
Trial report in Investigative ophthalmology & visual science, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- The Effects of Netarsudil Ophthalmic Solution on Aqueous Humor Dynamics in a Randomized Study in Humans.Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics · 2018Trial
- Assessing Agreement of Intraocular Pressure from Four Mechanistically Different Tonometers in the Eye Dynamics and Engineering Network Clinical Trial.Ophthalmology. GlaucomaTrial
- Eye Dynamics and Engineering Network Consortium: Baseline Characteristics of a Randomized Trial in Healthy Adults.Ophthalmology. GlaucomaTrial
- Objective Grading of Tonography Tracings for the Measurement of Outflow Facility.Translational vision science & technology · 2025Article
- Consensus Recommendations for Studies of Outflow Facility and Intraocular Pressure Regulation Using Ex Vivo Perfusion Approaches.Investigative ophthalmology & visual science · 2024Article
- Comparing IOP-Induced Scleral Deformations in the Myopic and Myopic Glaucoma Spectrums.Investigative ophthalmology & visual science · 2024Article
- How Myopia and Glaucoma Influence the Biomechanical Susceptibility of the Optic Nerve Head.Investigative ophthalmology & visual science · 2023Article
- Simulation of gravity- and pump-driven perfusion techniques for measuring outflow facility of ex vivo and in vivo eyes.PloS one · 2023Article
- Application of an organotypic ocular perfusion model to assess intravitreal drug distribution in human and animal eyes.Journal of the Royal Society, Interface · 2022Article
- Comparison of Corneal Wave Speed and Ocular Rigidity in Normal and Glaucomatous Eyes.Journal of glaucoma · 2021Article
- Effect of Timolol on Aqueous Humor Outflow Facility in Healthy Human Eyes.American journal of ophthalmology · 2019Article
- In vivo measurement of trabecular meshwork stiffness in a corticosteroid-induced ocular hypertensive mouse model.Proceedings of the National Academy of Sciences of the United States of America · 2019Article
- Aqueous Humor Dynamics of the Brown-Norway Rat.Investigative ophthalmology & visual science · 2018Article
- Article
- Re: Di Staso and Gaudio-Aqueous Outflow Facility after Periocular Triamcinolone Injection: A Preliminary Evaluation of the Falck Medical Applanation Tonometer.Journal of current glaucoma practiceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Purpose: It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. Methods: Fifty-six eyes from 28 healthy participants, ages 41 to 68 years, were included. Intraocular pressure (IOP) was measured in the sitting and supine positions with a pneumatonometer. With the subject in the supine position, IOP was recorded for 2 minutes by using a pneumatonometer with a 10-g weight and for 4 minutes by using a custom digital Schiøtz tonometer. Outflow facility was determined from the changes in pressure and intraocular volume and a standard assumed ocular rigidity coefficient for each instrument, respectively, and by using an ocular rigidity coefficient calculated by measuring pressure without and with a weight added to the pneumatonometer tip. Results: The outflow facility was 0.29 ± 0.09 μL/min/mm Hg by Schiøtz tonography and 0.24 ± 0.08 μL/min/mm Hg by pneumatonography (P < 0.001) when using the standard assumed constant ocular rigidity coefficient. Mean calculated ocular rigidity coefficient was 0.028 ± 0.01 μL-1, and outflow facility determined by using this coefficient was 0.23 ± 0.08 μL/min/mm Hg by Schiøtz tonography and 0.21 ± 0.07 μL/min/mm Hg by pneumatonography (P = 0.003). Outflow facilities measured by the two devices were correlated when the ocular rigidity was assumed (r = 0.60, P < 0.001) or calculated (r = 0.70, P < 0.001). Conclusions: Outflow facilities measured by pneumatonography were correlated with those measured by Schiøtz tonography, but Schiøtz tonography reported approximately 10% to 20% higher facilities when using the standard method. When ocular rigidity was determined for each eye, differences were smaller. Measurements from these devices cannot be compared directly.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.