Evidence map›Paper›PMID 28111452›Full record

ArticleThe American journal of case reports2017

Case Report of False-Negative Diffusion-Weighted Image of Brain Maggnetic Resonance Imaging (MRI) in Acute Ischemic Stroke.

Wei-Lun Chang, Ji-Ching Lai, Rong-Fu Chen, Han-Hwa Hu, Chau-Shiung Pan

Abstract readCase Reports
In one paragraph

Article in The American journal of case reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wei-Lun ChangDepartment of Neurology, Chang Hua Show Chwan Memorial Hospital, Changhua, Taiwan.
Ji-Ching LaiResearch Assistant Center, Chang Hua Show Chwan Health Care System, Changhua, Taiwan.
Rong-Fu ChenResearch Assistant Center, Chang Hua Show Chwan Health Care System, Changhua, Taiwan.
Han-Hwa HuGraduate Institute of Clinical Medicine and Department of Neurology, College of Medicine, Taipei Medical University and Hospital, Taipei, Taiwan.
Chau-Shiung PanDepartment of Neurology, Chang Hua Show Chwan Memorial Hospital, Changhua, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Acute ischemic stroke is a major cause of mortality and morbidity in Taiwan. Diffusion-weighted image (DWI) is a sensitive and common strategy used for imaging acute ischemic stroke. CASE REPORT We present a case of a negative DWI MRI for detecting acute ischemic stroke in a clinical setting. A 75-year-old male had a DWI performed after onset of symptoms suggesting acute ischemic stroke. The initial DWI result was negative at 72 hours of presentation. The neurological symptoms of the patient persisted and DWI was repeated. After 14 days, the DWI data confirmed and demonstrated an acute ischemic stroke. The delay in DWI confirmation, from symptom onset until DWI diagnosis, was 336 hours. CONCLUSIONS DWI may not have 100% sensitivity and accuracy in early stages of acute ischemic stroke. The time course to the development of abnormalities detected by DWI may be longer than anticipated.

Indexed as

Acute DiseaseAgedBrainBrain IschemiaFalse Negative ReactionsHumansMagnetic Resonance ImagingMale

Identifiers

PMID28111452