Compression forces used in the Norwegian Breast Cancer Screening Program.
Article in The British journal of radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Quantitative Evaluation of Pectoral Muscle Visualisation as an Indicator of Positioning Quality in Screening Mammography.Diagnostics (Basel, Switzerland) · 2026Article
- Automated Software Evaluation in Screening Mammography: A Scoping Review of Image Quality and Technique Assessment.Current oncology (Toronto, Ont.) · 2025Article
- The Impact of Automatic Exposure Control Technology on the In Vivo Radiation Dose in Digital Mammography: A Comparison Between Different Systems and Target/Filter Combinations.Diagnostics (Basel, Switzerland) · 2025Article
- Successes and challenges in extracting information from DICOM image databases for audit and research.The British journal of radiology · 2023Review
- To what extent are objectively measured mammographic imaging techniques associated with compression outcomes.The British journal of radiology · 2023Article
- Intra- and inter-rater reliability of compressed breast thickness, applied force, and pressure distribution in screening mammography.Acta radiologica open · 2021Article
- The Effect of Breast Size and Density in Turkish Women on Radiation Dose in Full-Field Digital Mammography.European journal of breast health · 2021Article
- Breast compression across consecutive examinations among females participating in BreastScreen Norway.The British journal of radiology · 2018Article
- Influence of breast compression pressure on the performance of population-based mammography screening.Breast cancer research : BCR · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveCompression is used in mammography to reduce breast thickness, which is claimed to improve image quality and reduce radiation dose. In the Norwegian Breast Cancer Screening Program (NBCSP), the recommended range of compression force for full-field digital mammography (FFDM) is 11-18 kg (108-177 N). This is the first study to investigate the compression force used in the programme.
methodsThe study included information from 17,951 randomly selected females screened with FFDM at 14 breast centres in the NBCSP, during January-March 2014. We investigated the applied compression force on the left breast in craniocaudal and mediolateral oblique views for breast centres, mammography machines within the breast centres and for the radiographers.
resultsThe mean compression force for all mammograms in the study was 116 N and ranged from 91 N to 147 N between the breast centres. The variation in compression force was wider between the breast centres than that between mammography machines (range 137-155 N) and radiographers (95-143 N) within one breast centre. Approximately 59% of the mammograms in the study complied with the recommended range of compression force.
conclusionA wide variation in applied compression force was observed between the breast centres in the NBCSP. This variation indicates a need for evidence-based recommendations for compression force aimed at optimizing the image quality and individualizing breast compression. Advances in knowledge: There was a wide variation in applied compression force between the breast centres in the NBCSP. The variation was wider between the breast centres than that between mammography machines and radiographers within one breast centre.