ArticleThe international journal of cardiovascular imaging2017
Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study.
Article in The international journal of cardiovascular imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Agatston-2.0: A next-generation AI-based coronary calcium quantification approach to improve risk stratification among individuals with zero Agatston scores - Part I: An AI-CVD Study within the Multi-Ethnic Study of Atherosclerosis and Framingham Heart Study.American journal of preventive cardiology · 2026Article
- Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study.European radiology · 2022Article
- Classification of moving coronary calcified plaques based on motion artifacts using convolutional neural networks: a robotic simulating study on influential factors.BMC medical imaging · 2021Article
- Fully automated quantification method (FQM) of coronary calcium in an anthropomorphic phantom.Medical physics · 2021Article
- Aortic valve calcification scoring with computed tomography: impact of iterative reconstruction techniques.The international journal of cardiovascular imaging · 2020Article
- Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology.European journal of hybrid imaging · 2020Review
- Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5-mm slice thickness using iterative reconstruction.Journal of applied clinical medical physics · 2020Article
- Influence of iterative reconstruction on coronary calcium scores at multiple heart rates: a multivendor phantom study on state-of-the-art CT systems.The international journal of cardiovascular imaging · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s corresponding to heart rates between 60 and 75 bpm. The inserts were scanned five times with routinely used CCS protocols at reference dose and 40 and 80% dose reduction on four high-end CT systems. Filtered back projection (FBP) and increasing levels of IR were applied. Noise levels were determined. CCS, quantified as Agatston and mass scores, were compared to physical mass and scores at FBP reference dose. For the reference dose in combination with FBP, noise level variation between CT systems was less than 18%. Decreasing dose almost always resulted in increased CCS, while at increased levels of IR, CCS decreased again. The influence of IR on CCS was smaller than the influence of dose reduction. At reference dose, physical mass was underestimated 3-30%. All CT systems showed similar CCS at 40% dose reduction in combinations with specific reconstructions. For some CT systems CCS was not affected at 80% dose reduction, in combination with IR. This multivendor study showed that radiation dose reductions of 40% did not influence CCS in a dynamic phantom using state-of-the-art CT systems in combination with specific reconstruction settings. Dose reduction resulted in increased noise and consequently increased CCS, whereas increased IR resulted in decreased CCS.