Evidence map›Paper›PMID 28102294›Full record

ArticleScientific reports2017

Novel Bio-functional Magnesium Coating on Porous Ti6Al4V Orthopaedic Implants: In vitro and In vivo Study.

Xiaokang Li, Peng Gao, Peng Wan, Yifeng Pei, Lei Shi, Bo Fan, Chao Shen, Xin Xiao, Ke Yang, Zheng Guo

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 67 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Xiaokang LiDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Peng GaoDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Peng WanInstitute of Metal Research, Chinese Academy of Science, Shenyang 110016, China.
Yifeng PeiDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Lei ShiDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Bo FanDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Chao ShenDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Xin XiaoDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Ke YangInstitute of Metal Research, Chinese Academy of Science, Shenyang 110016, China.
Zheng GuoDepartment of Orthopaedics, Xijing Hospital, Fourth Military Medical University, Xi'an, 710032, China.
Xijing Hospital · CNAir Force Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Titanium and its alloys with various porous structures are one of the most important metals used in orthopaedic implants due to favourable properties as replacement for hard tissues. However, surface modification is critical to improve the osteointegration of titanium and its alloys. In this study, a bioactive magnesium coating was successfully fabricated on porous Ti6Al4V by means of arc ion plating, which was proved with fine grain size and high film/substrate adhesion. The surface composition and morphology were characterized by X-ray diffraction and SEM equipped with energy dispersive spectroscopy. Furthermore, the in vitro study of cytotoxicity and proliferation of MC3T3-E1 cells showed that magnesium coated porous Ti6Al4V had suitable degradation and biocompatibility. Moreover, the in vivo studies including fluorescent labelling, micro-computed tomography analysis scan and Van-Gieson staining of histological sections indicated that magnesium coated porous Ti6Al4V could significantly promote bone regeneration in rabbit femoral condylar defects after implantation for 4 and 8 weeks, and has better osteogenesis and osteointegration than the bare porous Ti6Al4V. Therefore, it is expected that this bioactive magnesium coating on porous Ti6Al4V scaffolds with improved osteointegration and osteogenesis functions can be used for orthopedic applications.

Indexed as

Coated Materials, BiocompatibleMagnesiumOrthopedicsProstheses and ImplantsTitaniumAlloysAnimalsBone RegenerationCell ProliferationMaterials TestingMiceOsteoblastsPorosityRabbitsX-Ray MicrotomographyAlloysCoated Materials, BiocompatibleMagnesiumTitaniumtitanium alloy (TiAl6V4)

Identifiers

PMID28102294
PMCPMC5244406
OpenAlexW2579394323

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.