Evidence map›Paper›PMID 28101512›Full record

ArticleBioMed research international2016

Analysis of Carbon Fiber Reinforced PEEK Hinge Mechanism Articulation Components in a Rotating Hinge Knee Design: A Comparison of In Vitro and Retrieval Findings.

Ronja A Schierjott, Alexander Giurea, Hans-Joachim Neuhaus, Jens Schwiesau, Andreas M Pfaff, Sandra Utzschneider, Gianluca Tozzi, Thomas M Grupp

Open access · hybridAbstract readComparative Study
In one paragraph

Article in BioMed research international, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 19 citations in OpenAlex.

  1. Fatigue failure of constrained total knee replacement: A case report.Journal of clinical orthopaedics and trauma · 2025
    Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 3 countries.

Ronja A SchierjottSchool of Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK; Aesculap AG, Research & Development, Am Aesculap-Platz, 78532 Tuttlingen, Germany.ORCID 0000-0002-0624-1978
Alexander GiureaDepartment of Orthopaedics, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
Hans-Joachim NeuhausDepartment of Traumatology and Orthopaedics, St. Vincenz Hospital, Am Stein 24, 58706 Menden, Germany.ORCID 0000-0002-4083-7193
Jens SchwiesauAesculap AG, Research & Development, Am Aesculap-Platz, 78532 Tuttlingen, Germany; Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Ludwig Maximilians University Munich, Campus Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany.ORCID 0000-0001-6581-3238
Andreas M PfaffAesculap AG, Research & Development, Am Aesculap-Platz, 78532 Tuttlingen, Germany.
Sandra UtzschneiderDepartment of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Ludwig Maximilians University Munich, Campus Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany.ORCID 0000-0003-2065-432X
Gianluca TozziSchool of Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK.
Thomas M GruppAesculap AG, Research & Development, Am Aesculap-Platz, 78532 Tuttlingen, Germany; Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Ludwig Maximilians University Munich, Campus Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany.ORCID 0000-0002-1068-7497
Ludwig-Maximilians-Universität München · DEUniversity of Portsmouth · GBSt. Vincenz-Krankenhaus Limburg · DEVienna General Hospital · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) represents a promising alternative material for bushings in total knee replacements, after early clinical failures of polyethylene in this application. The objective of the present study was to evaluate the damage modes and the extent of damage observed on CFR-PEEK hinge mechanism articulation components after in vivo service in a rotating hinge knee (RHK) system and to compare the results with corresponding components subjected to in vitro wear tests. Key question was if there were any similarities or differences between in vivo and in vitro damage characteristics. Twelve retrieved RHK systems after an average of 34.9 months in vivo underwent wear damage analysis with focus on the four integrated CFR-PEEK components and distinction between different damage modes and classification with a scoring system. The analysis included visual examination, scanning electron microscopy, and energy dispersive X-ray spectroscopy, as well as surface roughness and profile measurements. The main wear damage modes were comparable between retrieved and in vitro specimens (

Indexed as

Arthroplasty, Replacement, KneeEquipment Failure AnalysisAgedBenzophenonesCarbonCarbon FiberFemaleHumansKetonesKnee ProsthesisPolyethylene GlycolsPolymersProsthesis DesignProsthesis FailureBenzophenonesCarbonCarbon FiberKetonespolyetheretherketonePolyethylene GlycolsPolymers

Identifiers

PMID28101512
PMCPMC5213741
OpenAlexW2565211637

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked