Trial reportDiabetes care2017
Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes.
Trial report in Diabetes care, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis.BMJ (Clinical research ed.) · 2018Pooled it
- Predictive hyperglycemia and hypoglycemia minimization: In-home double-blind randomized controlled evaluation in children and young adolescents.Pediatric diabetes · 2018Trial
- Early Stages of Automated Insulin Delivery.Diabetes technology & therapeutics · 2025Review
- Early Stages of Automated Insulin Delivery.Journal of diabetes science and technology · 2025Review
- Evidence from clinical trials on high-risk medical devices in children: a scoping review.Pediatric research · 2024Article
- The changing landscape of automated insulin delivery in the management of type 1 diabetes.Endocrine connections · 2023Review
- Effectiveness and safety of a model predictive control (MPC) algorithm for an artificial pancreas system in outpatients with type 1 diabetes (T1D): systematic review and meta-analysis.Diabetology & metabolic syndrome · 2022Review
- Closed-loop control in insulin pumps for type-1 diabetes mellitus: safety and efficacy.Expert review of medical devices · 2020Review
- Combining continuous glucose monitoring and insulin pumps to automatically tune the basal insulin infusion in diabetes therapy: a review.Biomedical engineering online · 2019Review
- Role of continuous glucose monitoring in the management of glycogen storage disorders.Journal of inherited metabolic disease · 2018Article
- Insulin delivery and nocturnal glucose control in children and adolescents with type 1 diabetes.Expert opinion on drug delivery · 2017Review
- Insulin Infusion Sets and Continuous Glucose Monitoring Sensors: Where the Artificial Pancreas Meets the Patient.Diabetes technology & therapeutics · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
19 authors.
Funding
Abstract
objectiveThe objective of this study was to determine the safety, feasibility, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system compared with predictive low-glucose insulin suspension (PLGS) alone in overnight glucose control. RESEARCH DESIGN AND
methodsA 42-night trial was conducted in 30 individuals with type 1 diabetes in the age range 15-45 years. Participants were randomly assigned each night to either PHHM or PLGS and were blinded to the assignment. The system suspended the insulin pump on both the PHHM and PLGS nights for predicted hypoglycemia but delivered correction boluses for predicted hyperglycemia on PHHM nights only. The primary outcome was the percentage of time spent in a sensor glucose range of 70-180 mg/dL during the overnight period.
resultsThe addition of automated insulin delivery with PHHM increased the time spent in the target range (70-180 mg/dL) from 71 ± 10% during PLGS nights to 78 ± 10% during PHHM nights (
conclusionsThe addition of a predictive hyperglycemia minimization component to our existing PLGS system was shown to be safe, feasible, and effective in overnight glucose control.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials