Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis.

Randy W Purves, Satendra Prasad, Michael Belford, Albert Vandenberg, Jean-Jacques Dunyach

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 47 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Randy W PurvesDepartment of Plant Sciences, University of Saskatchewan, 51 Campus Drive, Saskatoon, SK, Canada. randy.purves@usask.ca.
Satendra PrasadThermoFisher Scientific, 355 River Oaks Parkway, San Jose, CA, USA.
Michael BelfordThermoFisher Scientific, 355 River Oaks Parkway, San Jose, CA, USA.
Albert VandenbergDepartment of Plant Sciences, University of Saskatchewan, 51 Campus Drive, Saskatoon, SK, Canada.
Jean-Jacques DunyachThermoFisher Scientific, 355 River Oaks Parkway, San Jose, CA, USA.
Thermo Fisher Scientific (United States) · USUniversity of Saskatchewan · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The implementation of an aerodynamic mechanism to improve ion sampling between nanoelectrospray (n-ESI) and FAIMS was recently reported for proteomic analyses. This investigation explores the new FAIMS interface for small molecule analysis at high liquid flow rates and includes an examination of key differences in ionization between heated-ESI (HESI) and n-ESI. The sheath gas, critical for desolvation with HESI, affects FAIMS operation as higher FAIMS gas flow rates are required to achieve sufficient desolvation. Gas flow rate experiments also uncovered m/z discrimination with the conventional design as larger (slower moving) m/z ions experienced larger signal intensity losses than smaller m/z ions due to the desolvation gas flow having a greater drag effect on slower moving ions. The modified inlet in new FAIMS dampens the gas drag, making the HESI source more amenable as less m/z bias and significantly lower %RSD values were observed. Furthermore, a larger radius inner electrode in new FAIMS enables significantly higher E/N (electric field/number gas density) to be achieved using the existing waveform generator. Thus, new FAIMS signal intensities using only nitrogen improved 1.25- to 2-fold compared with the conventional design and 50% helium. Adding helium to the new FAIMS gave no significant improvements. The larger inner electrode also decreased ion focusing capabilities, and the effect on peak separation and ion intensity was examined in detail. The peak capacity of new FAIMS was approximately double that of conventional FAIMS; separation of seven low m/z ions gave a peak capacity of 37.7 using the gas additive 2-propanol. Graphical Abstract ᅟ.

Indexed as

DesolvationDMSElectrospray ionizationFAIMSGas additivesIon focusingIon mobilityMass SpectrometrySmall molecules

Identifiers

PMID28097537
OpenAlexW2578797227

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.