Evidence map›Paper›PMID 28097109›Full record

ArticleHip & pelvis2016

Accuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty.

Jong Ki Shin, Seung Min Son, Tae Woo Kim, Won Chul Shin, Jung Sub Lee, Kuen Tak Suh

Open access · hybridAbstract read
In one paragraph

Article in Hip & pelvis, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
0.9field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Article
  3. Shifting to an app-based method of preoperative templating in orthopaedic surgery.OTA international : the open access journal of orthopaedic trauma · 2024
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jong Ki ShinDepartment of Orthopaedic Surgery, Pusan National University Hospital, Busan, Korea.
Seung Min SonDepartment of Orthopaedic Surgery, Pusan National University Hospital, Busan, Korea.
Tae Woo KimDepartment of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Yangsan, Korea.
Won Chul ShinDepartment of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Yangsan, Korea.
Jung Sub LeeDepartment of Orthopaedic Surgery, Pusan National University Hospital, Busan, Korea.
Kuen Tak SuhDepartment of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Yangsan, Korea.
Pusan National University Hospital · KRPusan National University Yangsan Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePreoperative on-screen templating is a method of using acetate templates on digital images. The aim of the present study was to evaluate the accuracy, intra- and interobserver reliabilities of preoperative on-screen templating using digital radiographs for total hip arthroplasty (THA). MATERIALS AND

methodsTwo hundred patients with hip disease who were treated with primary cementless THA were retrospectively evaluated. The accuracy of on-screen templating was assessed by comparing the predicted prosthesis sizes with the actual sizes used operatively. The inter- and intraobserver reliabilities of the templating results were also evaluated.

resultsThe prosthesis prediction accuracy within ±one size was 96.6% for the cup size and 97.8% for the stem size. The inter- and intraobserver reliabilities for the implant size were substantial (kappa>0.70). The intra- and interobserver reliabilities for the leg length discrepancy and femoral offset difference using the intraclass correlation coefficient ranged from 0.89 to 0.97.

conclusionPreoperative on-screen templating using digital radiographs showed substantial accuracy and reliability for implant prediction. It is an effective method for predicting the size of implant, correcting the leg length discrepancy and restoring the femoral offset.

Indexed as

Acetate templateDigital radiographyHipTotal hip arthroplasty

Identifiers

PMID28097109
PMCPMC5240321
OpenAlexW2569044207

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.