Evidence map›Paper›PMID 28084559›Full record

ArticleJournal of medical ultrasonics (2001)2017

Apodized adaptive beamformer.

Hideyuki Hasegawa

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Hideyuki HasegawaGraduate School of Science and Engineering, University of Toyama, Toyama, 930-8555, Japan. hasegawa@eng.u-toyama.ac.jp.ORCID http://orcid.org/0000-0003-0709-7821

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeA number of studies aimed at improvement of ultrasound image quality, such as spatial resolution and contrast, have been conducted. Apodization is known as an important factor that determines image quality. However, in the case of amplitude and phase estimation (APES) beamforming, a kind of adaptive beamformer that has been employed in medical ultrasound recently, only rectangular apodization has been used in the previous studies. In this study, apodization was employed in adaptive beamforming, and its effects on image quality were examined in phantom experiments.

methodsWe recently proposed a modified APES beamformer that reduces the computational complexity significantly using sub-aperture beamforming. In this study, the total receiving aperture was divided into four sub-apertures, and the APES beamforming was applied to the output from the four sub-apertures. Before the delay-and-sum (DAS) beamforming in each sub-aperture, echoes received by individual transducer elements were apodized with rectangular, Gaussian, and two Hanning functions, where the apodization with two Hanning functions realized lateral modulation of the ultrasonic field. The lateral spatial resolution was evaluated by the full width at half maximum of an echo from a string phantom, and the image contrast was evaluated using a cyst phantom.

resultsThe modified APES beamformer realized a significantly better spatial resolution of 0.38 mm than that of the conventional delay-and-sum beamformer (0.67 mm), even with rectangular apodization. Using Gaussian apodization, the spatial resolution was further improved to 0.34 mm, and contrast was also improved from 4.3 to 5.1 dB. Furthermore, an image obtained by the modified APES beamformer with apodization consisting of two Hanning functions was better "tagged" as compared with the conventional DAS beamformer with the same apodization.

conclusionApodization was shown to be effective in adaptive beamforming, and an image obtained by the adaptive beamformer with lateral modulation seemed to have potential for improvement of the accuracy in measurement of tissue lateral motion.

Indexed as

AlgorithmsImage Processing, Computer-AssistedPhantoms, ImagingUltrasonographyAdaptive beamformerApodizationCovariance matrixImage quality

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.