ReviewDer Orthopade2017
[Partial exchange in total hip arthroplasty : What can we combine?]
Review in Der Orthopade, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- [Revision surgery for inlay, neck and head failure of hip endoprostheses with fixed metal components].Operative Orthopadie und Traumatologie · 2026Article
- Efficacy and safety of tranexamic acid combined with low molecular weight heparin versus fondaparinux sodium following total knee arthroplasty: a retrospective cohort study.Frontiers in pharmacology · 2025Article
- Feasibility of a Shape-Memory-Alloy-Actuator System for Modular Acetabular Cups.Bioengineering (Basel, Switzerland) · 2024Article
- [Partial or full component exchange in hip revision? : The relevance of off-label use and mix & match].Orthopadie (Heidelberg, Germany) · 2022Review
- EFORT recommendations for off-label use, mix & match and mismatch in hip and knee arthroplasty.EFORT open reviews · 2021Review
- Long-term outcome after revision of hip arthroplasty with the BioBall® adapter system in multimorbid patients.Journal of orthopaedic translation · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn case of hip revision arthroplasty, one component (cup/stem) is often well fixed and does not need to be exchanged. The newly implanted component needs to be compatible with the well-fixed implant. The combination of implants from different companies leads to "mix and match" or even mismatch between the implants. OBJECTIVES AND
methodsThe objective of this work was to describe possible combinations including their specifications that need to be considered in partial exchange of hip prostheses. For this purpose the literature, surgical techniques of companies and judgements concerning this topic were analysed and our own results and experiences were included. RESULTS AND
conclusionsPartial revision arthroplasty can be challenging and needs to be planned in detail. In case of isolated cup or inlay revision with exchange of a modular head the cone of the stem needs to be identified. A ceramic head may be used in revision with a titanium sleeve even from a different company as long as they are compatible. Patients however need to give their informed consent for this mix and match procedure. This procedure is done frequently and good study results support this, however from a juristic point of view a definite recommendation cannot be given. If the inlay of a cup is replaced, the original inlay should be used. If this is not available anymore, it can be manufactured as a special product in many cases. If this is also not possible, an inlay can also be cemented into a well-fixed cup. Biomechanical and clinical studies support this off-label technique. In case of an isolated exchange of the stem with a ceramic inlay that is retained in a well-fixed cup, the revision stem and ceramic head need to be from the same company as the cup. In case of ceramic fracture, a ceramic head with a titanium sleeve should be combined with a PE or ceramic inlay, a metal head or inlay should never be used.
Indexed as
Identifiers
28083683What OpenQuestion holds
Registered trials