ArticleDevelopmental neuroscience2017
EEG Monitoring Technique Influences the Management of Hypoxic-Ischemic Seizures in Neonates Undergoing Therapeutic Hypothermia.
Article in Developmental neuroscience, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 23 citations in OpenAlex.
- [Expert consensus on the clinical management of therapeutic hypothermia for neonatal hypoxic-ischemic encephalopathy (2026)].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2026Article
- Electrographic monitoring for seizure detection in the neonatal unit: current status and future direction.Pediatric research · 2024Review
- Association of Hospital Resource Utilization With Neurodevelopmental Outcomes in Neonates With Hypoxic-Ischemic Encephalopathy.JAMA network open · 2023Article
- Predictive value of early amplitude integrated electroencephalogram (aEEG) in sleep related problems in children with perinatal hypoxic-ischemia (HIE).BMC pediatrics · 2021Article
- Current and Future Uses of Continuous EEG in the NICU.Frontiers in pediatrics · 2021Review
- Potential biomarkers for neuroinflammation and neurodegeneration at short and long term after neonatal hypoxic-ischemic insult in rat.Journal of neuroinflammation · 2019Article
- Predictive value of early EEG for seizures in neonates with hypoxic-ischemic encephalopathy undergoing therapeutic hypothermia.Pediatric research · 2018Article
- The Johns Hopkins Neurosciences Intensive Care Nursery Tenth Anniversary (2009-2019): A Historical Reflection and Vision for the Future.Child neurology openReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
Electroencephalogram (EEG) monitoring techniques for neonatal hypoxia-ischemia (HI) are evolving over time, and the specific type of EEG utilized could influence seizure diagnosis and management. We examined whether the type of EEG performed affected seizure treatment decisions (e.g., the choice and number of antiseizure drugs [ASDs]) in therapeutic hypothermia-treated neonates with HI from 2007 to 2015 in the Johns Hopkins Hospital Neonatal Intensive Care Unit. During this period, 3 different EEG monitoring protocols were utilized: Period 1 (2007-2009), single, brief conventional EEG (1 h duration) at a variable time during therapeutic hypothermia treatment, i.e., ordered when a seizure was suspected; Period 2 (2009-2013), single, brief conventional EEG followed by amplitude-integrated EEG for the duration of therapeutic hypothermia treatment and another brief conventional EEG after rewarming; and Period 3 (2014-2015), continuous video-EEG (cEEG) for the duration of therapeutic hypothermia treatment (72 h) plus for an additional 12 h during and after rewarming. One hundred and sixty-two newborns were included in this retrospective cohort study. As a function of the type and duration of EEG monitoring, we assessed the risk (likelihood) of receiving no ASD, at least 1 ASD, or ≥2 ASDs. We found that the risk of a neonate being prescribed an ASD was 46% less during Period 3 (cEEG) than during Period 1 (brief conventional EEG only) (95% CI 6-69%, p = 0.03). After adjusting for initial EEG and MRI results, compared with Period 1, there was a 38% lower risk of receiving an ASD during Period 2 (95% CI: 9-58%, p = 0.02) and a 67% lower risk during Period 3 (95% CI: 23-86%, p = 0.01). The risk ratio of receiving ≥2 ASDs was not significantly different across the 3 periods. In conclusion, in addition to the higher sensitivity and specificity of continuous video-EEG monitoring, fewer infants are prescribed an ASD when undergoing continuous forms of EEG monitoring (aEEG or cEEG) than those receiving conventional EEG. We recommend that use of continuous video-EEG be considered whenever possible, both to treat seizures more specifically and to avoid overtreatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.