Evidence map›Paper›PMID 28081186›Full record

ArticlePloS one2017

Mechanical Compression Effects on the Secretion of vWF and IL-8 by Cultured Human Vein Endothelium.

Dar Weiss, Sharon Avraham, Ruth Guttlieb, Lee Gasner, Alina Lotman, Oren M Rotman, Shmuel Einav

Abstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. [Application of micro-bolus injection and piezoelectric sensors to improve the safety of radiopharmaceuticals bolus injection].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dar WeissDepartment of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel.
Sharon AvrahamDepartment of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel.
Ruth GuttliebDepartment of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel.
Lee GasnerDepartment of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel.
Alina LotmanDepartment of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel.
Oren M RotmanDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America.
Shmuel EinavDepartment of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Short peripheral catheters are ubiquitous in today's healthcare environment enabling effective delivery of fluids and medications directly into a patient's vasculature. However, complications related to their use, such as short peripheral catheter thrombophlebitis (SPCT), affect up to 80% of hospitalized patients. While indwelling within the vein, the catheters exert prolonged constant pressure upon the endothelium which can trigger inflammation processes. We have developed and studied an in-vitro model of cultured endothelial cells subjected to mechanical compression of modular self-designed weights, and explored their inflammatory response by quantification of two key biomarkers- vWF and IL-8. Evaluation was performed by ELISA immunoassay and processing of vWF-labeled immunofluorescence images. We found that application of weights correspond to 272 Pa yielded increased release of vWF and IL-8 up to 150% and 250% respectively, comparing to the exertion of 136 Pa. Analyses of the immunofluorescence images revealed significantly longer and more extracellular vWF-strings as well as higher intensity stained-pixels in cells exposed to elevated pressures. The release of both factors found to be significantly dependent on the extent of the exerted pressure. The research shed a light on the relationship between induced mechanical compression and the pathogenesis of SPCT. Minimizing, let alone eliminating the contact between the catheter and the vein wall will mitigate the pressure acting on the endothelium, thereby reducing the secretion of inflammatory factors and lessen the incidence of SPCT.

Indexed as

Stress, MechanicalCells, CulturedEndothelium, VascularEnzyme-Linked Immunosorbent AssayHumansImage Processing, Computer-AssistedInterleukin-8Microscopy, Fluorescencevon Willebrand FactorInterleukin-8von Willebrand Factor

Identifiers

PMID28081186
PMCPMC5230793

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.