Evidence map›Paper›PMID 28078485›Full record

ArticleJournal of the American Society for Mass Spectrometry2017

A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging.

Juha-Pekka Hieta, Anu Vaikkinen, Samuli Auno, Heikki Räikkönen, Markus Haapala, Gianmario Scotti, Jaakko Kopra, Petteri Piepponen, Tiina J Kauppila

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Mass Spectrometry Imaging ofJournal of the American Society for Mass Spectrometry · 2021
    Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution.Journal of the American Society for Mass Spectrometry · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Juha-Pekka HietaFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Anu VaikkinenFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Samuli AunoFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Heikki RäikkönenFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Markus HaapalaFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Gianmario ScottiFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Jaakko KopraFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Petteri PiepponenFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland.
Tiina J KauppilaFaculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Helsinki, Finland. tiina.kauppila@helsinki.fi.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In mass spectrometry imaging of tissues, the size of structures that can be distinguished is determined by the spatial resolution of the imaging technique. Here, the spatial resolution of IR laser ablation is markedly improved by increasing the distance between the laser and the focusing lens. As the distance between the laser and the lens is increased from 1 to 18 m, the ablation spot size decreases from 440 to 44 μm. This way, only the collimated center of the divergent laser beam is directed on the focusing lens, which results in better focusing of the beam. Part of the laser energy is lost at longer distance, but this is compensated by focusing of the radiation to a smaller area on the sample surface. The long distance can also be achieved by a set of mirrors, between which the radiation travels before it is directed to the focusing lens and the sample. This method for improving the spatial resolution can be utilized in mass spectrometry imaging of tissues by techniques that utilize IR laser ablation, such as laser ablation electrospray ionization, laser ablation atmospheric pressure photoionization, and matrix-assisted laser desorption electrospray ionization. Graphical Abstract ᅟ.

Indexed as

Ambient mass spectrometryIR laser ablationLaser ablation atmospheric pressure photoionizationLaser ablation electrospray ionizationLaser focusingMass spectrometry imagingMatrix-assisted laser desorption electrospray IonizationMetastable-induced chemical ionizationSpatial resolutionTissue imaging

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.