Trunk Motion System (TMS) Using Printed Body Worn Sensor (BWS) via Data Fusion Approach.

Mohammad Iman Mokhlespour Esfahani, Omid Zobeiri, Behzad Moshiri, Roya Narimani, Mohammad Mehravar, Ehsan Rashedi, Mohamad Parnianpour

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mohammad Iman Mokhlespour EsfahaniDepartment of Industrial and Systems Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061, USA. mokhlespour@vt.edu.
Omid ZobeiriDepartment of Biomedical Engineering, McGill University, Montréal, QC H3A 2B4, Canada. omid.zobeiri@mail.McGill.ca.
Behzad MoshiriControl and Intelligent Processing, Center of Excellence, School of Electrical and Computer Engineering, University of Tehran, Tehran 14395-515, Iran. moshiri@ut.ac.ir.
Roya NarimaniLaboratory of Wearable Technologies and Neuromusculoskeletal Research, School of Mechanical Engineering, Sharif University of Technology, Tehran 11155-9567, Iran. narimani@sharif.edu.
Mohammad MehravarMusculoskeletal Rehabilitation Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz 6135733133, Iran. mohammad.mehravar@gmail.com.
Ehsan RashediDepartment of Industrial and Systems Engineering, Rochester Institute of Technology, Rochester, NY 14623-5603, USA. exreie@rit.edu.
Mohamad ParnianpourLaboratory of Wearable Technologies and Neuromusculoskeletal Research, School of Mechanical Engineering, Sharif University of Technology, Tehran 11155-9567, Iran. parnianpour@sharif.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Human movement analysis is an important part of biomechanics and rehabilitation, for which many measurement systems are introduced. Among these, wearable devices have substantial biomedical applications, primarily since they can be implemented both in indoor and outdoor applications. In this study, a Trunk Motion System (TMS) using printed Body-Worn Sensors (BWS) is designed and developed. TMS can measure three-dimensional (3D) trunk motions, is lightweight, and is a portable and non-invasive system. After the recognition of sensor locations, twelve BWSs were printed on stretchable clothing with the purpose of measuring the 3D trunk movements. To integrate BWSs data, a neural network data fusion algorithm was used. The outcome of this algorithm along with the actual 3D anatomical movements (obtained by Qualisys system) were used to calibrate the TMS. Three healthy participants with different physical characteristics participated in the calibration tests. Seven different tasks (each repeated three times) were performed, involving five planar, and two multiplanar movements. Results showed that the accuracy of TMS system was less than 1.0°, 0.8°, 0.6°, 0.8°, 0.9°, and 1.3° for flexion/extension, left/right lateral bending, left/right axial rotation, and multi-planar motions, respectively. In addition, the accuracy of TMS for the identified movement was less than 2.7°. TMS, developed to monitor and measure the trunk orientations, can have diverse applications in clinical, biomechanical, and ergonomic studies to prevent musculoskeletal injuries, and to determine the impact of interventions.

Indexed as

body worn sensorsensor fusiontrunk movementwearable system

Identifiers

PMID28075342
PMCPMC5298685

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390