Evidence map›Paper›PMID 28073093›Full record

ArticleClinical biomechanics (Bristol, Avon)2017

Subject-specific finite element analysis of the carpal tunnel cross-sectional to examine tunnel area changes in response to carpal arch loading.

Piyush Walia, Ahmet Erdemir, Zong-Ming Li

Abstract read
In one paragraph

Article in Clinical biomechanics (Bristol, Avon), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Piyush WaliaHand Research Laboratory, Cleveland Clinic, Cleveland, OH, United States; Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, United States.
Ahmet ErdemirComputational Biomodeling (CoBi) Core, Cleveland Clinic, Cleveland, OH, United States; Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, United States.
Zong-Ming LiHand Research Laboratory, Cleveland Clinic, Cleveland, OH, United States; Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, United States; Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH, United States; Department of Physical Medicine and Rehabilitation, Cleveland Clinic, Cleveland, OH, United States. Electronic address: liz4@ccf.org.

Funding

Biomechanical Treatment of Carpal Tunnel SyndromeR01AR068278 · NIAMS · UNIVERSITY OF ARIZONA · PI LI, ZONG-MING · 2015 to 2019
$2.8M
NIAMS NIH HHS R01 AR068278
6 · The paper itself

Abstract

backgroundManipulating the carpal arch width (i.e. distance between hamate and trapezium bones) has been suggested as a means to increase carpal tunnel cross-sectional area and alleviate median nerve compression. The purpose of this study was to develop a finite element model of the carpal tunnel and to determine an optimal force direction to maximize area.

methodsA planar geometric model of carpal bones at hamate level was reconstructed from MRI with inter-carpal joint spaces filled with a linear elastic surrogate tissue. Experimental data with discrete carpal tunnel pressures (50, 100, 150, and 200mmHg) and corresponding carpal bone movements were used to obtain material property of surrogate tissue by inverse finite element analysis. The resulting model was used to simulate changes of carpal arch widths and areas with directional variations of a unit force applied at the hook of hamate.

findingsInverse finite element model predicted the experimental area data within 1.5% error. Simulation of force applications showed that carpal arch width and area were dependent on the direction of force application, and minimal arch width and maximal area occurred at 138° (i.e. volar-radial direction) with respect to the hamate-to-trapezium axis. At this force direction, the width changed to 24.4mm from its initial 25.1mm (3% decrease), and the area changed to 301.6mm

interpretationThe findings of the current study guide biomechanical manipulation to gain tunnel area increase, potentially helping reduce carpal tunnel pressure and relieve symptoms of compression median neuropathy.

Indexed as

AdultBiomechanical PhenomenaCarpal BonesCarpal Tunnel SyndromeFemaleFinite Element AnalysisHumansMagnetic Resonance ImagingMedian NerveModels, BiologicalTendonsTrapezium BoneWrist JointCarpal tunnelCross-sectional areaMechanics

Identifiers

PMID28073093
PMCPMC5319899

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.