Evidence map›Paper›PMID 28070866›Full record

ArticleCardiovascular engineering and technology2017

Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation.

Thuy Pham, Fanwei Kong, Caitlin Martin, Qian Wang, Charles Primiano, Raymond McKay, John Elefteriades, Wei Sun

Abstract read
In one paragraph

Article in Cardiovascular engineering and technology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Interactive Effects Between Papillary Muscle Approximation and Ring Annuloplasty to Repair Functional Mitral Regurgitation in Enlarged Ventricles.Functional imaging and modeling of the heart : ... International Workshop, FIMH ..., proceedings. FIMH (Conference) · 2025
    Article
  8. Article
  9. Article
  10. Review
  11. The effects of leaflet material properties on the simulated function of regurgitant mitral valves.Journal of the mechanical behavior of biomedical materials · 2023
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. New Insights into Valve Hemodynamics.Rambam Maimonides medical journal · 2020
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Thuy PhamThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.
Fanwei KongThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.
Caitlin MartinThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.
Qian WangThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.
Charles PrimianoCardiology Department of Hartford Hospital, Hartford, CT, USA.
Raymond McKayCardiology Department of Hartford Hospital, Hartford, CT, USA.
John ElefteriadesAortic Institute of Yale-New Haven Hospital, New Haven, CT, USA.
Wei SunThe Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA. wei.sun@bme.gatech.edu.
Georgia Institute of Technology · USHartford Hospital · USThe Wallace H. Coulter Department of Biomedical Engineering · USYale New Haven Hospital · US

Funding

Probabilistic Modeling of Stenotic Aortic Valve InterventionR01HL104080 · NHLBI · UNIVERSITY OF CONNECTICUT STORRS · PI SUN, WEI · 2011 to 2015
$1.9M
Biomechanical study on aortic-mitral coupling in transcatheter aortic valve replacementR21HL127570 · NHLBI · GEORGIA INSTITUTE OF TECHNOLOGY · PI SUN, WEI · 2016 to 2017
$441k
NHLBI NIH HHS R01 HL104080NHLBI NIH HHS R21 HL127570
6 · The paper itself

Abstract

Functional mitral regurgitation (FMR) is a significant complication of left ventricular dysfunction and strongly associated with a poor prognosis. In this study, we developed a patient-specific finite element (FE) model of the mitral apparatus in a FMR patient which included: both leaflets with thickness, annulus, chordae tendineae, and chordae insertions on the leaflets and origins on the papillary muscles. The FE model incorporated human age- and gender-matched anisotropic hyperelastic material properties, and MV closure at systole was simulated. The model was validated by comparing the FE results from valve closure simulation with the in vivo geometry of the MV at systole. It was found that the FE model could not replicate the in vivo MV geometry without the application of tethering pre-tension force in the chordae at diastole. Upon applying the pre-tension force and performing model optimization by adjusting the chordal length, position, and leaflet length, a good agreement between the FE model and the in vivo model was established. Not only were the chordal forces high at both diastole and systole, but the tethering force on the anterior papillary muscle was higher than that of the posterior papillary muscle, which resulted in an asymmetrical gap with a larger orifice area at the anterolateral commissure resulting in MR. The analyses further show that high peak stress and strain were found at the chordal insertions where large chordal tethering forces were found. This study shows that the pre-tension tethering force plays an important role in accurately simulating the MV dynamics in this FMR patient, particularly in quantifying the degree of leaflet coaptation and stress distribution. Due to the complexity of the disease, the patient-specific computational modeling procedure of FMR patients presented should be further evaluated using a large patient cohort. However, this study provides useful insights into the MV biomechanics of a FMR patient, and could serve as a tool to assist in pre-operative planning for MV repair or replacement surgical or interventional procedures.

Indexed as

Finite Element AnalysisModels, BiologicalAgedChordae TendineaeHeart VentriclesHumansImage Processing, Computer-AssistedMaleMitral Valve InsufficiencyMultidetector Computed TomographyPapillary MusclesReproducibility of ResultsSystoleChordae tendineaeFinite element simulationMitral regurgitationMitral valveMulti-slice computed tomographyPatient-specific

Identifiers

PMID28070866
PMCPMC5321865
OpenAlexW2571107087

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.