Pulse sequence considerations for simulation and postimplant dosimetry of prostate brachytherapy.

Jingfei Ma, Marinus A Moerland, Aradhana M Venkatesan, Tharakeswara K Bathala, Rajat J Kudchadker, Kristy K Brock, Steven J Frank

Open access · greenAbstract read
In one paragraph

Article in Brachytherapy. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Jingfei MaDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX. Electronic address: jma@mdanderson.org.
Marinus A MoerlandDepartment of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands.
Aradhana M VenkatesanDepartment of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX.
Tharakeswara K BathalaDepartment of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX.
Rajat J KudchadkerDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
Kristy K BrockDepartment of Radiation Oncology, University of Michigan, Ann Arbor, MI.
Steven J FrankDepartment of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX.
The University of Texas MD Anderson Cancer Center · USUniversity Medical Center Utrecht · NLUniversity of Michigan–Ann Arbor · US

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Fabien Delerue · 1985 to 2026
$290.8M
NCI NIH HHS P30 CA016672
6 · The paper itself

Abstract

purposeThe purpose of this work is to present a brief review of MRI physics principles pertinent to prostate brachytherapy, and a summary of our experience in optimizing protocols for prostate brachytherapy applications. METHODS AND MATERIALS: We summarized essential MR imaging characteristics and their interplays that need to be considered for prostate brachytherapy applications. These include spatial resolution, signal-to-noise ratio, image contrast, artifacts, geometric distortion, specific absorption rate, and total scan time. We further described the optimization of the protocols for three pulse sequences: three-dimensional (3D) fast-spoiled gradient echo sequence for T1-weighted imaging, 3D fast-spin echo sequence for T2-weighted imaging, and 3D fast imaging in steady-state precession sequence for combined T1 and T2-weighed imaging. The utilization of an endorectal coil was also described.

resultsUsing the optimized protocols, we acquired high-quality images of the entire prostate within 3-5 minutes for each sequence. These images display the desired image contrasts and a spatial resolution that is equal to or better than 0.59 mm × 0.73 mm × 1.2 mm. While 3D fast-spoiled gradient echo sequence and 3D fast-spin echo sequence depict radioactive seed markers and anatomic structures separately, 3D fast imaging in steady-state precession sequence demonstrates great promise for imaging both seed markers and prostate anatomy simultaneously in a single acquisition.

conclusionsWe have optimized current MRI protocols and demonstrated that the anatomic structures and positive contrast radioactive seed markers for prostate post-implant dosimetry can be adequately imaged either separately or simultaneously using different pulse sequences within a total scan time of 3-5 minutes each.

Indexed as

MRI protocolsProstate brachytherapyPulse sequencesRadioactive seeds