Evidence map›Paper›PMID 28060961›Full record

ArticlePloS one2017

Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

Yurie Obata, Maki Mizogami, Daniel Nyhan, Dan E Berkowitz, Jochen Steppan, Viachaslau Barodka

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Yurie ObataDivision of Cardiac Anesthesia, Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, United States of America.ORCID http://orcid.org/0000-0003-0764-3917
Maki MizogamiDepartment of Anesthesiology and Reanimatology, University of Fukui, Fukui, Japan.
Daniel NyhanDivision of Cardiac Anesthesia, Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, United States of America.
Dan E BerkowitzDivision of Cardiac Anesthesia, Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, United States of America.
Jochen SteppanDivision of Cardiac Anesthesia, Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, United States of America.
Viachaslau BarodkaDivision of Cardiac Anesthesia, Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, United States of America.
Johns Hopkins University · USUniversity of Fukui · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTransesophageal echocardiography (TEE) is increasingly replacing thermodilution pulmonary artery catheters to assess hemodynamics in patients at high risk for cardiovascular morbidity. However, one of the drawbacks of TEE compared to pulmonary artery catheters is the inability to measure real time stroke volume (SV) and cardiac output (CO) continuously. The aim of the present proof of concept study was to validate a novel method of SV estimation, based on pulse wave velocity (PWV) in patients undergoing cardiac surgery.

methodsThis is a retrospective observational study. We measured pulse transit time by superimposing the radial arterial waveform onto the continuous wave Doppler waveform of the left ventricular outflow tract, and calculated SV (SVPWV) using the transformed Bramwell-Hill equation. The SV measured by TEE (SVTEE) was used as a reference.

resultsA total of 190 paired SV were measured from 28 patients. A strong correlation was observed between SVPWV and SVTEE with the coefficient of determination (R2) of 0.71. A mean difference between the two (bias) was 3.70 ml with the limits of agreement ranging from -20.33 to 27.73 ml and a percentage error of 27.4% based on a Bland-Altman analysis. The concordance rate of two methods was 85.0% based on a four-quadrant plot. The angular concordance rate was 85.9% with radial limits of agreement (the radial sector that contained 95% of the data points) of ± 41.5 degrees based on a polar plot.

conclusionsPWV based SV estimation yields reasonable agreement with SV measured by TEE. Further studies are required to assess its utility in different clinical situations.

Indexed as

Cardiac OutputPulse Wave AnalysisStroke VolumeAgedCardiac Surgical ProceduresCatheterization, Swan-GanzEchocardiography, TransesophagealFemaleHemodynamicsHumansMaleMiddle AgedRetrospective Studies

Identifiers

PMID28060961
PMCPMC5218503
OpenAlexW2569841177

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.