Evidence map›Paper›PMID 28050814›Full record

ArticleClinical orthopaedics and related research2017

What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

Raveesh Daniel Richard, Thomas R Bowen

Abstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Editorial Comment: 2016 Musculoskeletal Infection Society Proceedings.Clinical orthopaedics and related research · 2017
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors.

Raveesh Daniel RichardDepartment of Orthopaedics, Geisinger Medical Center, 100 N Academy Avenue, Danville, PA, 17822, USA. raveeshrichard@gmail.com.
Thomas R BowenDepartment of Orthopaedics, Geisinger Medical Center, 100 N Academy Avenue, Danville, PA, 17822, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. QUESTIONS/PURPOSES: What orthopaedic operating room surfaces are contaminated with bioburden?

methodsWhen energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries.

resultsAll surfaces had bioburden. The ATP RLUs (mean ± SD) are reported for each surface in ascending order: the OR preparation table (postdraping; 8.3 ± 3.4), inside the sterilized pan (9.2 ± 5.5), the inside of the Bair Hugger™ hose (212.5 ± 155.7), supply closet countertops (281.7 ± 236.7), OR light handles (647.8 ± 903.7), the OR preparation table (predraping; 1054 ± 387.5), the Clark-socket attachment (1135.7 ± 705.3), patient positioners used for total hip and spine positioning (1201.7 ± 1144.9), Bovie machine buttons (1264.5 ± 638.8), Bair Hugger™ buttons (1340.8 ± 1064.1), tourniquet machine buttons (1666.5 ± 2144.9), computer keyboard (1810.8 ± 929.6), and the right side of the OR table headboard (2539 ± 5635.8).

conclusionsATP bioluminescence is a novel method to measure cleanliness within the orthopaedic OR and can help identify environmental trouble spots that can potentially lead to increased infection rates. Future studies correlating ATP bioluminescence findings with microbiology cultures could add to the clinical utility of this technology. CLINICAL RELEVANCE: Surfaces such as the undersurface of the OR table headboard, Bair Hugger™ buttons, and tourniquet machine buttons should be routinely cleansed as part of an institutional protocol. Although correlation between ATP bioluminescence and clinical infection was not evaluated in this study, it is the subject of future research. Specifically, evaluating microbiology samples taken from these environmental surfaces and correlating them with increased bioburden found with ATP bioluminescence technology can help promote improved surgical cleaning practices.

Indexed as

Equipment ContaminationOperating RoomsOrthopedic ProceduresAdenosine TriphosphateColony Count, MicrobialHumansInfection ControlLuminescent MeasurementsAdenosine Triphosphate

Identifiers

PMID28050814
PMCPMC5449321

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.