ArticleJournal of clinical and diagnostic research : JCDR2016
Comparing Assay Performance of ELISA and Chemiluminescence Immunoassay in Detecting Antibodies to Hepatitis B Surface Antigen.
Article in Journal of clinical and diagnostic research : JCDR, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 33 citations in OpenAlex.
- Environmentally Safe Synthesis of Gold Nanoparticles for Antigen Detection in CLIA System.ACS omega · 2025Article
- A universal point-of-care immunochromatographic test for the serodiagnosis of hepatitis D.Journal of clinical microbiology · 2025Article
- Immune response to hepatitis B vaccine among children under 5 years in Africa: a meta-analysis.Tropical medicine and health · 2024Review
- Viral Diagnosis of Hepatitis B and Delta: What We Know and What Is Still Required? Specific Focus on Low- and Middle-Income Countries.Microorganisms · 2022Review
- Development of a Chemiluminescence Assay for Total N-Terminal Propeptide of Type I Collagen and Its Evaluation in Lung Transplantation.Journal of analytical methods in chemistry · 2022Article
- Highly sensitive protein detection using recombinant spores and lateral flow immunoassay.Analytical and bioanalytical chemistry · 2021Article
- The performance of the chemiluminescent immunoassay for measuring serum myeloperoxidase and proteinase 3 antibodies.Journal of clinical laboratory analysis · 2021Article
- Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods.Journal of blood medicine · 2021Article
- Article
- Article
- Quantitative serological antibody testing for suspected neuroborreliosis.Journal of neurology · 2020Article
- Comparative Evaluation and Measure of Accuracy of ELISAs, CLIAs, and ECLIAs for the Detection of HIV Infection among Blood Donors in China.The Canadian journal of infectious diseases & medical microbiology = Journal canadien des maladies infectieuses et de la microbiologie medicale · 2020Article
- A retrospective serological survey of hepatitis B virus infection in Northeast China.BMC infectious diseases · 2019Article
- Method Comparison (Agreement) Studies: Myths and Rationale.Journal of clinical and diagnostic research : JCDR · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionAntibodies to Hepatitis B surface Antigen (Anti-HBs) levels are measured as markers for immune response to vaccination and in decision making for post-exposure prophylaxis against Hepatitis-B. Several immunoassay formats are used to measure Anti-HBs, thus carrying the possibility of variation in measured levels between different assays. This study compares the performance of Chemiluminescence Immunoassay (CLIA) against Enzyme-linked Immunosorbent Assay (ELISA) in measuring Anti-HBs titer by looking into concordance between the two test reports.
aimTo compare the agreement between ELISA and CLIA in measurement of Anti-HBs antibody titers. MATERIALS AND
methodsThis prospective comparative study conducted at Kasturba Medical College, Manipal measured consecutive serum samples (69) sent for anti-HBs levels during May-June 2016 using both CLIA (Abbott Architect) and ELISA (Bio-Rad). Anti-HBs values of ≤10mIU/ml was considered as non-protective and >10mIU/ml as protective. The agreement between the tests in classifying the antibody titers as non-protective or protective was computed using Kappa coefficient, and the difference in individual titer values between the tests compared using Bland-Altman plot on SPSS (v.15).
resultsOut of the 69 samples analysed, 18 samples (26.1%) were of health-care personnel and remaining of patients. Agreement between ELISA and CLIA in identifying the antibody titers as protective and non-protective were 96.5% and 90.9% respectively, resulting in an agreement of 0.84. The coefficient-of-variation of ELISA and CLIA were 74.5% and 113.1%, respectively. Three value based discordant results were noted; two samples deemed protective by ELISA were reported as non-protective by CLIA. One non-protective titer by ELISA was reported as protective by CLIA.
conclusionAnalytical agreement is good between the two immunoassays. However there are some discrepancies in quantitative measurement. This may have been due the variation in the standard calibrators used in each assay. Though CLIA showed more variation in the values, it has the advantage of being automated test with low turn around time. Therefore, both the test methodologies can be reliably used in place of each other for detection of Anti- HBs titer.