ArticleEar and hearing
Normative Wideband Reflectance, Equivalent Admittance at the Tympanic Membrane, and Acoustic Stapedius Reflex Threshold in Adults.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 91 citations in OpenAlex.
- Differentiating Middle Ear and Medial Olivocochlear Effects on Transient-Evoked Otoacoustic Emissions.Journal of the Association for Research in Otolaryngology : JARO · 2017Trial
- Rapid Characterization of Middle-Ear Muscle Reflexes Using Swept Elicitors.Journal of the Association for Research in Otolaryngology : JARO · 2026Article
- [Supplementary use of broadband absorbance measurements for classification of normal hearing].HNO · 2026Article
- The Effects of Broadband Elicitor Duration on Transient-Evoked Otoacoustic Emissions and a Psychoacoustic Measure of Gain Reduction.Journal of the Association for Research in Otolaryngology : JARO · 2025Article
- A Critique of the Stenger Test.Audiology research · 2025Article
- Test-Retest Differences in the Wideband Middle Ear Muscle Reflex.American journal of audiology · 2025Article
- Reflection function, reflectance, and area function measurements in ears of children and adults.The Journal of the Acoustical Society of America · 2024Article
- Article
- The effects of broadband elicitor duration on a psychoacoustic measure of cochlear gain reduction.The Journal of the Acoustical Society of America · 2023Article
- Brainstem auditory physiology in children with listening difficultiesHearing research · 2023Article
- Wideband Acoustic Reflex Measurement.Seminars in hearing · 2023Review
- The Rise and Fall of Aural Acoustic Immittance Assessment Tools.Seminars in hearing · 2023Review
- The middle ear muscle reflex: Current and future role in assessing noise-induced cochlear damage.The Journal of the Acoustical Society of America · 2023Article
- Changes in Acoustic Absorbance Pre- and Post-Cochlear Implantation.American journal of audiology · 2022Article
- Wideband tympanometry as a diagnostic tool for Meniere's disease: a retrospective case-control study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022Article
- The Impacts of Noise Exposure on the Middle Ear Muscle Reflex in a Veteran Population.American journal of audiology · 2022Article
- Understanding degraded speech leads to perceptual gating of a brainstem reflex in human listeners.PLoS biology · 2021Article
- The effect of broadband elicitor laterality on psychoacoustic gain reduction across signal frequency.The Journal of the Acoustical Society of America · 2021Article
- Auditory dysfunction in type 2 Stickler Syndrome.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021Article
- The relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition at positive and negative signal-to-noise ratios.The Journal of the Acoustical Society of America · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
objectivesWideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle ear function across a wide frequency range, compared with traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal-hearing adults and investigate test-retest reliability using a longitudinal design.
designA longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 26 years). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately 1 month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip that were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared.
resultsMean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared with ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 μsec, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 μsec. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability.
conclusionsNormative data for the WAI test battery revealed minor differences for results at ambient pressure compared with tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared with ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle ear function.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.